Vermont Casting H33BDVRRNP Indoor Fireplace User Manual


 
20
Pyromaster© H33BDVRRN/P
10004798
Only glass approved by the CFM
Corporation should be used on this
fireplace.
The top louvre panel is
removed by lifting the
panel vertically and pulling
it away from the appliance.
(Fig. 35) The lower access
door is hinged along the
bottom edge and is folded
down to allow access.
1. Turn the fireplace OFF (including the pilot).
2. If the unit has been operating allow time for the
components to cool.
3. Remove the top louvre assembly.
4. Open the lower louvre panel.
5. Release the two clamps securing the lower edge of
the window frame assembly by pulling down on the
handles. (Fig. 36)
6. Tilt the window frame assembly out slightly at the
bottom, lift the window frame assembly up and away
from the fireplace.
7. To replace the window frame assembly reverse the
procedure.
It is necessary to periodically clean glass. During start-
up condensation, which is normal, forms on the inside
of the glass. This condensation causes lint, dust and
other airborne particles to cling to glass surface.
Also initial paint curing may deposit a slight film on the
glass. It is therefore recommended the glass be
cleaned two or three times with a non-ammonia based
household cleaner and warm water (We recommend
gas fireplace glass cleaner) within the first few weeks
of operation.
After the initial cleaning process the glass should be
cleaned two or three times during each operating
season depending on the environment in the house.
The use of any non-approved replacement glass will
void all product warranties.
Care must be taken to avoid breakage of the glass.
Under no circumstances should this appliance be
operated without the window frame assembly in
place, or with the glass in a damaged condition.
Replacement glass (complete with gasket) is
available through your CFM Harris dealer and
should only be installed by a licensed qualified
service person.
Clean the glass after the first two weeks
of operation.
Operating Instructions
Glass Information
Window Frame Assembly Removal
Glass Cleaning
Louvre Removal
1.
2.
Louvre
Glass Panel
FP1221
Fig. 35 Remove top louvre
panel.
Lower
Clamps
Window
Frame
Assembly
Window
Frame
Assembly
Pull Clamp
Hook
Push Clamp
Handle
FP771b
Fig. 36 Window frame assembly removal.
Installation of Logs,
Lava Rock & Ember Material
Unpack the logs from packaging and remove each log
from its wrapping materials.
The logs are fragile and should be
handled with care. Keep the packaging
material out of the reach of children and
dispose of the material in a safe manner.
The individual logs can be easily identified by the
numbers cast on the underside of each log.