48
DV360/580 Series Direct Vent Gas Fireplace
20010667
Optional Accessories
Fan Kits
FK12 Fan Assembly
1. Open louvre assembly bottom.
2. Install FK12 fan in back of unit between hearth sup
-
ports. (Fig. 79)
3. Secure fan on velcro strips.
4. Power to the fan can be supplied by plugging the
supply lead into a conveniently located wall socket
or by using a hard-wired EB-1 connector box.
5. Be sure fan motor does not touch hearth supports.
FP1004
Fan placement
DV360/580 Series
1/25/00 djt
Cold Air Box
Side View
Front of
Unit
Hearth Pan
Base Pan
FK12 Fan
FP1004
Fig. 79 FK12 Fan Kit placement.
FK24 Fan Assembly
Fan specifications: 120 volt, 60 Hz, .75 Amp.
This fan does not need regular maintenance, however
periodic cleaning is required. Check the area under the
control door and in front of the fan and wipe or vacuum
at least once a month during the operating season.
Should this fan require servicing, the power supply must
be disconnected.
The FK24 comes with the electrical cord attached.
1. Slide fan assembly from the left side into the fire-
place opening, line up mounting holes with screw
studs on back of fireplace and fasten with #10 - 24
hex nuts. (Fig. 80)
2. Install thermal sensor on bottom of firebox using #10
- 24 hex nuts.
3. (Option A) - Place electronic fan speed control box
on bottom of fireplace base, lining up mounting holes
with screw studs. Fasten fan speed control box with
#10 - 24 hex nuts.
(Option B) - The speed control can be installed in an
electrical box at normal wall switch height for conve-
nient access.
4. The power supply may be connected in 2 ways:
Method A
Route the 6’ (1.8m) lead fitted to the unit to a conve
-
niently located wall socket.
Method B
If the EB-1 receptacle box (Pt. #ZA1200) was cor
-
rectly connected when the unit was installed, the
fan lead can be directly plugged into the EB-1 plug
socket.
5. Whether wiring directly to the fan junction box (Op-
tion A) or into the EB1 (electrical box, Option B) first
ensure cable is secured using box connector.
The fireplace, when installed must be elec
-
trically connected and grounded in accor-
dance with local codes, with the current
CSA C22.1 Canadian Electrical Code or for
US installations, follow local codes and
the National Electrical Code, ANSI/NFPA
No. 70.
Hard (Direct) Wire Hook Up
First connect ground wire to ground stud located on
the base of either box. Black wire from supply should
connect to the variable speed switch. Alternate speed
switch wire connects to temperature sensor. Alternate
lead from sensor connects to fan. Alternate fan lead
connects back to the white supply wire. (Fig. 81)
Any electrical rewiring of this fan must be
completed by a qualified electrician.
Turn off all power before hook up.
H
I
L
O
O
F
F
O
N
O
F
F
P
I
L
O
T
O
F
F
E
A
P
I
L
O
T
T
P
T
H
FP1026
FK24
fan placement
1/27/00 djt
Electrical Box
Heat Sensor
Fan
Fan Speed
Switch
Gas Line
Valve
FP1026
Fig. 80 FK24 fan placement.
Black
White
Ground
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature
Sensor
Speed
Control
FP1025
Fig. 81 FK24 fan wiring.