Vermont Casting 1610 Stove User Manual


 
21
Defiant 1610 Non-Catalytic Woodburning Stove
30002850
Install the Optional Ash Door Heat Shield
Many installations will require the use of the supplied
ash door heat shield. Refer to the “Floor Protection”
sections starting on Page 10 to determine if your instal-
lation requires the use of the ash door heat shield.
1. Remove the two Phillips pan head screws from the
ash door.
2. Insert the screws through the ash door heat shield
(from the painted side), place the 5/16” spacers over
the screws, and carefully thread them back into the
original holes. (Fig. 23) The curved lip should be
upward, under the ashlip of the stove.
3. Tighten securely.
ST539
Attach
ash door
heat shield
11/00
ST538
Spacers
Fig. 23 Install the ashdoor heat shield.
Adjust the Leg Levellers
Lift the stove slightly so there is no weight on the leg
while making the adjustment.
Reverse the Flue Collar (If necessary)
Reverse the flue collar by removing the two screws that
attach it to the back of the stove. Be sure the gasket
around the flue collar opening is in position when you
screw the collar back onto the stove.
ST540
Assembly
handle
11/00
ST540
Fig. 25 Assemble the front door handle.
DEFIANT
ST539
attach
thermostat
handle
11/00
ST539
Fig. 24 Attach the thermostat handle.
Attach the Damper Handle
Use the 1/4” -20 x 3” screw to attach the damper handle
to the damper stub on the left side.
Attach the Primary Air Thermostat Handle
The primary air thermostat handle is the smaller of the
two black handles. Secure the handle to the stub on
the right side of the stove with an 8-32 x 2” slot head
machine screw. (Fig. 24)
Assemble the Removable Insert Handle
The ceramic removable insert handle opens and closes
the front doors. Remove after each use, and store it in
the handle holder behind the right front leg. Assemble
the handle by passing the 3³⁄₈" screw through the
ceramic shaft and into the bright metal nub. (Fig. 25)
Tighten carefully until snug.