Vermont Casting 1610 Stove User Manual


 
14
Defiant 1610 Non-Catalytic Woodburning Stove
30002850
Defiant NC Clearance Chart for 6” Connections ONLY
Stove Clearance
Stove Installed
Parallel to Wall
Unprotected Surfaces Protected Surfaces
1
Side Rear Corners Side Rear
3
Corners
Chimney Connector Clearance
Unprotected Vertical Surfaces Protected Vertical Surfaces
Single-wall connector
Clearance to Combustibles in Front of Stove
48” (1219 mm)
26¹⁄₂” (673 mm) 21¹⁄₂” (546 mm)
All Installations
Stove Installed
Parallel to Wall
Stove
in
Corner
Stove
in
Corner
Top exit with no
connector heat shields.
Flue collar shield installed
Single-wall connector
with shields
(G) 26” (H) 18” (I) 27” (J) 13” (K) 26” (L) 20”
(660 mm) (457 mm) (686 mm) (330 mm) (660 mm) (508 mm)
(A) 26” (B) 31” (C) 27” (D) 13” (E) 26” (F) 20”
(660 mm) (787 mm) (686 mm) (330 mm) (660 mm) (508 mm)
Top exit double-wall chim
-
ney connector*. Flue collar
shield installed
Top exit with heat shields
on connector. Flue collar
shield installed.
2
Single-wall connector
(Horizontal)
13¹⁄₂” (343 mm) 21¹⁄₂” (546 mm)
18¹⁄₂” (470 mm) 17¹⁄₂“ (445 mm)
* Using a listed double wall oval to 6” round connector.
Rear exit
(S) 24” (T) 21” N/A (U) 10” (V) 21” N/A
(610 mm) (533 mm) (254 mm) (533 mm)
(M) 26” (N) 23” (O) 16” (P) 10” (Q) 22” (R) 17”
(660 mm) (584 mm) (706 mm) (254 mm) (559 mm) (432 mm)
Double-wall chimney
connector
Unprotected Ceiling Surfaces Protected Ceiling Surfaces
15” (381 mm) Not measured
1. When wall protection is used, a ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling must
surround the pipe in installations where the chimney penetrates the ceiling.
2. The connector pipe heat shield must extend 36” (914 mm) above the flue collar. When this shield is used, a single wall pipe may
continue vertically unshielded.
3. With protected wall surfaces, the rear clearance must be increased by 3” (76 mm) if the flue collar heat shield is not used. The
flue collar shield is required when using connector pipe shields and always with unprotected surfaces.
A minimum ceiling height of 8 feet (2.4 m) measured from the base of the stove is required for all installations.