Vermont Casting 1610 Stove User Manual


 
15
Defiant 1610 Non-Catalytic Woodburning Stove
30002850
Defiant NC Clearance Chart for 8” Connections ONLY
Stove Clearance
1
Stove Installed
Parallel to Wall
Unprotected Surfaces Protected Surfaces
Side Rear Corners Side Rear
2
Corners
Chimney Connector Clearance
Unprotected Vertical Surfaces Protected Vertical Surfaces
Single-wall connector
Clearance to Combustibles in Front of Stove
48” (1219 mm)
29¹⁄₂” (749 mm) 9¹⁄₂” (241 mm)
All Installations
Stove Installed
Parallel to Wall
Stove
in
Corner
Stove
in
Corner
Top exit with no
connector heat shields.
Flue collar shield installed
Single-wall connector
with shields
(G) 26”
4
(H) 17”
4
(I) 25”
4
(J) 11” (K) 15” (L) 9”
(660 mm) (430 mm) (635 mm) (279 mm) (381 mm) (229 mm)
(A) 24”
3
(B) 35”
3
(C) 25”
3
(D) 11” (E) 15” (F) 9”
(610 mm) (889 mm) (635 mm) (279 mm) (381 mm) (229 mm)
Top exit double-wall
chimney connector*. Flue
collar shield installed
Top exit with heat shields
on connector. Flue collar
shield installed
Single-wall connector
(Horizontal)
11¹⁄₂” (292 mm) 9¹⁄₂” (241 mm)
16¹⁄₂” (419 mm) 5¹⁄₂” (140 mm)
* Using a listed double wall oval to round connector.
Rear exit
(S) 21” (T) 21” N/A (U) 8” (V) 21” N/A
(533 mm) (533 mm) (203 mm) (533 mm)
(M) 25” (N) 22” (O) 14” (P) 8” (Q) 11” (R) 6”
(635 mm) (559 mm) (356 mm) (203 mm) (279 mm) (152 mm)
Double-wall chimney
connector
Unprotected Ceiling Surfaces Protected Ceiling Surfaces
30” (762 mm) 19” (483 mm)
1. Most installations require a ceiling heat shield 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling that must
surround the pipe when the chimney penetrates the ceiling. Refer to Notes 3 and 4 below for the only exceptions to this. The
ceiling heat shield is always required if clearances are reduced using wall protection.
2. With protected wall surfaces, the rear clearance must be increased by 3” (76 mm) if the flue collar heat shield is not used. The
flue collar shield is required when using connector pipe shields and always with unprotected surfaces.
3. In installations where the ceiling height is 9 feet (2.7 m) or more and if wall protection is not used, the ceiling heat shield is not
necessary.
4. Connector pipe heat shields must extend the entire length of the connector pipe up to 9 feet (2.7 m). In installations where the
ceiling height is 10 feet (3 m) or more and if wall protection is not used, the ceiling heat shield is not necessary.
A minimum ceiling height of 8 feet (2.4 m) measured from the base of the stove is required for all installations.