Vermont Casting 1610 Stove User Manual


 
17
Defiant 1610 Non-Catalytic Woodburning Stove
30002850
48"
(1220 mm)
48"
(1220 mm)
48"
(1220 mm)
ST498
Defiant
Wall shield B
11/00
Fig. 17 Parallel installation with rear wall pass-through, two
wall shields. Reduced clearances to both rear and side walls.
Wall shields may meet at corner if desired. Wall pass-through
must comply with codes.
Refer to “Special Installations.”
ST498
48"
(1220 mm)
48"
(1220 mm)
48"
(1220 mm)
48"
(1220 mm)
ST497
Defiant
wall shield A
11/00
Fig. 16 Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls.
Wall shields may meet at corner if desired. Shielding for con-
nector is centered behind connector.
ST497
Refer to
IMPORTANT
Note on This
Page
48"
(1220 mm)
48"
(1220 mm)
48"
(1220 mm)
48"
(1220 mm)
ST499
Defiant
Wall Shield C
11/00
ST499
Fig. 18 Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shield MUST
meet at corner.
Refer to
IMPORTANT
Note on This
Page
Refer to
IMPORTANT
Note on This
Page
IMPORTANT: when the stove is installed with 8” con-
nector pipe, wall shields must extend to within 1” (25
mm) of the ceiling (up to 9’ (2.7 m)) due to potentially
higher pipe temperatures. With 6” connections, the wall
shields only need to extend to a height of 48” (1220
mm) as shown in the grey shaded areas of Figures 16,
17 and 18.