Distance from the Center of the Flue Collar to the Wall for 8” Connections ONLY
The information on this page is helpful in planning stove placement, particularly in those installations with
chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must
adhere to the guidelines in the clearance chart on Page 15 for 8” connections.
Defiant With Flue Collar Heat Shield Only
Unprotected Surfaces
Protected Surfaces
Parallel Installations
Corner
Installations
Corner
Installations
Parallel Installations
Defiant With Flue Collar Heat Shield and Shielded Connector:
Defiant With Flue Collar Heat Shield and Double-wall Connector:
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
39
³⁄₄ 34³⁄₈ 35” 26³⁄₄ 14³⁄₈ 19”
(1010 mm) (873 mm) (889 mm) (680 mm) (365 mm) (483 mm)
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
41
³⁄₄ 16³⁄₈ 35” 26³⁄₄ 14³⁄₈ 19”
(1060 mm) (416 mm) (889 mm) (680 mm) (365 mm) (483 mm)
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
40
³⁄₄ 21³⁄₈ 24” 23³⁄₄ 10³⁄₈ 16”
(1035 mm) (543 mm) (610 mm) (603 mm) (264 mm) (406 mm)
ST511
Intrepid
flue centerline
Diagrams
11/16/00
*
A
B
C
*
D
E
F
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this