Vermont Casting 1450 Stove User Manual


 
15
Encore 1450 Non-Catalytic Woodburning Stove
30002425
21” (533 mm) 7” (178 mm)
9” (229 mm) 3” (76 mm)
3
6” Connector 8” Connector
15” (381 mm) 9” (229 mm) *
(A) 17” (B) 29” (C) 28” (D) 8”
1,4
(E) 15”
1,4
(F) 8”
1,4
(432 mm) (737 mm) (711 mm) (203 mm) (380 mm) (203 mm)
(G) 17” (H) 17” (I) 19” (J) 8”
1
(K) 11”
1
(L) 7”
1
(432 mm) (432 mm) (483 mm) (203 mm) (280 mm) (178 mm)
(M) 18” (N) 24”
5
N/A (P) 8” (Q) 6” Collar N/A
(457 mm) (610 mm) (203 mm) 11” (279 mm)
8” Collar
19” (483 mm)
(G) 18” (H) 6” Collar (I) 19”
(457 mm) 23” (584 mm) (483 mm) *
8” Collar
17” (432 mm)
Stove Clearance
Unprotected Surfaces Protected Surfaces
Chimney Connector Clearance
Single-wall connector,
No chimney connector
heat shields
Single-wall connector,
Chimney connector heat
shields installed
Double-wall connector
Clearance to Combustibles in Front of Stove
All Installations (S) 48” (1219 mm)
* Clearances with double-wall connectors and protected surfaces have not been tested for the Encore NC.
1. A ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling, must surround the chimney connec
-
tor in installations in which the chimney connector penetrates the ceiling.
2. The chimney connector shield extends only to 36” (914
mm) above the flue collar.
3. The ceiling heat shield required when the chimney connector shields are used should meet the wall protector. This will require
trimming the ceiling shield along the line of intersection with the wall protector.
4. The vertical collar heat shield is not required when wall protection is installed according to this manual.
5. All rear exit installations require a wall shield when combustible material is within 12” (305 mm) of the center of the rear wall
pass through. The shield must be 24” (610 mm) in diameter, be spaced 1” (25 mm) from the wall and must surround the chim-
ney connector.
Encore NC Clearance Chart
For use with either 6” or 8” flue collar/chimney connection
Stove Installed Stove Stove Installed Stove
Parallel to Wall in Corner Parallel to Wall in Corner
Side Rear Corners Side Rear Corners
No stove heat shields,
vertical flue collar heat
shield installed (except
where noted)
Top Exit, single-wall
chimney connector heat
shields
2
, vertical flue col-
lar h.s. installed
Rear Exit
Top Exit, double-wall
chimney connector,
vertical flue collar heat
shield installed