PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR
Heating Capacity
50XT036 High
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C)
--10 (--23.3) 0 (--17.7) 10 (--12.2) 17 (--8.3) 20 (--6.6)
EDB
_F
(_C)
CFM
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Total Integ Total Integ Total Integ Total Integ Total Integ
60
(15.6)
1050 8.62 7.93 1.43 11.33 10.43 1.60 14.73 13.52 1.78 17.57 16.02 1.92 18.91 17.15 1.99
1200 8.70 8.01 1.43 11.45 10.53 1.59 14.88 13.66 1.77 17.76 16.19 1.90 19.11 17.33 1.97
70
(21.1)
1050 8.34 7.68 1.59 11.02 10.14 1.77 14.26 13.09 1.97 16.99 15.49 2.12 18.32 16.61 2.19
1200 8.44 7.77 1.59 11.14 10.25 1.77 14.42 13.24 1.96 17.20 15.68 2.10 18.53 16.81 2.17
80
(26.7)
1050 7.96 7.32 1.74 10.60 9.76 1.95 13.78 12.65 2.17 16.38 14.93 2.33 17.63 15.99 2.40
1200 8.07 7.43 1.74 10.74 9.88 1.94 13.93 12.79 2.15 16.59 15.12 2.31 17.86 16.19 2.38
50XT036 High Con’t.
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C)
30 (--1.1) 40 (4.4) 47 (8.3) 50 (10) 60 (15.5)
EDB
_F
(_C)
CFM
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Total Integ Total Integ Total Integ Total Integ Total Integ
60
(15.6)
1050 23.95 20.99 2.22 29.99 29.99 2.51 34.51 34.51 2.69 36.57 36.57 2.79 43.09 43.09 3.12
1200 24.20 21.21 2.20 30.20 30.20 2.45 34.82 34.82 2.67 36.95 36.95 2.74 43.39 43.39 2.88
70
(21.1)
1050 23.16 20.29 2.44 28.99 28.99 2.73 33.82 33.82 2.98 35.98 35.98 3.08 42.90 42.90 3.44
1200 23.44 20.54 2.41 29.28 29.28 2.71 33.60 33.60 2.90 35.59 35.59 3.00 43.10 43.10 3.30
80
(26.7)
1050 22.38 19.61 2.67 28.03 28.03 2.99 32.65 32.65 3.24 34.87 34.87 3.37 42.66 42.66 3.75
1200 22.66 19.86 2.64 28.36 28.36 2.94 33.00 33.00 3.21 34.97 34.97 3.29 42.80 42.80 3.69
50XT