Carrier 50XT Heat Pump User Manual


 
13
PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR
Heating Capacity
50XT024 Low
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C)
--10 (--23.3) 0 (--17.7) 10 (--12.2) 17 (--8.3) 20 (--6.6)
EDB
_F
(_C)
CFM
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Total Integ Total Integ Total Integ Total Integ Total Integ
60
(15.6)
525 2.95 2.72 1.05 4.89 4.50 1.11 7.22 6.63 1.18 8.74 7.97 1.22 9.48 8.60 1.24
600 2.99 2.75 1.04 4.97 4.58 1.09 7.31 6.71 1.17 8.89 8.11 1.20 9.64 8.74 1.22
70
(21.1)
525 2.81 2.59 1.22 4.72 4.34 1.29 6.73 6.18 1.35 8.26 7.53 1.38 8.97 8.14 1.40
600 2.87 2.64 1.21 4.80 4.41 1.28 6.87 6.30 1.34 8.40 7.66 1.37 9.13 8.28 1.38
80
(26.7)
525 2.61 2.41 1.37 4.45 4.09 1.46 6.26 5.75 1.52 7.78 7.10 1.56 8.46 7.68 1.57
600 2.66 2.46 1.36 4.53 4.16 1.44 6.38 5.86 1.51 7.92 7.22 1.54 8.60 7.80 1.56
50XT024 Low Con’t.
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C)
30 (--1.1) 40 (4.4) 47 (8.3) 50 (10) 60 (15.5)
EDB
_F
(_C)
CFM
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Capacity
MBtuh
Total
System
KW
Total Integ Total Integ Total Integ Total Integ Total Integ
60
(15.6)
525 12.17 10.66 1.30 15.20 15.20 1.37 17.28 17.28 1.41 18.16 18.16 1.44 19.43 19.43 1.44
600 12.37 10.84 1.27 15.22 15.22 1.33 16.79 16.79 1.37 16.85 16.85 1.36 16.78 16.78 1.29
70
(21.1)
525 11.60 10.17 1.46 14.55 14.55 1.54 16.84 16.84 1.61 17.86 17.86 1.64 20.96 20.96 1.71
600 11.80 10.34 1.43 14.80 14.80 1.50 16.80 16.80 1.54 17.64 17.64 1.57 18.39 18.39 1.53
80
(26.7)
525 11.00 9.64 1.64 13.91 13.91 1.72 16.15 16.15 1.79 17.17 17.17 1.83 20.53 20.53 1.91
600 11.21 9.83 1.61 14.16 14.16 1.68 16.40 16.40 1.74 17.36 17.36 1.77 20.33 20.33 1.85
LEGEND
Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat)
db —DryBulb
kW — Total Power Input (Includes Compressor Motor Power Input Outdoor-- Fan Motor Input, and Indoor--Fan Motor Input)
rh Relative Humidity
NOTES:
Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.
50XT