Carrier 50GL 024-060 Air Conditioner User Manual


 
Table 16—50GL/50JZ Cooling & Heating Dry Coil ICM Airflow
Small Cabinet
UNIT
SIZE
CFM ADJUST
PIN SELECT
LO PIN NOM PIN HI PIN
EXTERNAL STATIC
PRESSURE RANGE
0.0–0.4 0.4–0.7 0.7–1.0 0.0–0.4 0.4–0.7 0.7–1.0 0.0–0.4 0.4–0.7 0.7–1.0
024
COOLING 800 725 885 805 730 990 930 855
COOLING
DEHUMIDIFY
715 670 715 695 645 795 775 745
HEAT PUMP
COMFORT (50JZ Only)
720 660 790 745 685 890 850 785
030
COOLING 1010 920 825 1105 1030 930 1255 1160 1050
COOLING
DEHUMIDIFY
890 845 795 890 865 825 1010 980 925
HEAT PUMP
COMFORT (50JZ Only)
945 850 765 1020 965 895 1140 1105 995
036
COOLING 1110 1025 970 1235 1175 1115 1400 1355 1280
COOLING
DEHUMIDIFY
990 960 910 990 975 940 1125 1110 1085
HEAT PUMP
COMFORT (50JZ Only)
1035 975 910 1160 1080 1020 1305 1275 1220
Heat Pump Efficiency
and
Cooling
pin selections deliver equal airflow
Table 17—50GL/50JZ Cooling & Heating Dry Coil ICM Airflow
Large Cabinet
UNIT
SIZE
CFM ADJUST
PIN SELECT
LO PIN NOM PIN HI PIN
EXTERNAL STATIC
PRESSURE RANGE
0.1–1.0 0.1–1.0 0.1–1.0
042
COOLING 1100 1225 1410
COOLING
DEHUMIDIFY
980 980 1125
HEAT PUMP
COMFORT (50JZ Only)
990 1100 1265
048
COOLING 1260 1400 1610
COOLING
DEHUMIDIFY
1120 1120 1290
HEAT PUMP
COMFORT (50JZ Only)
1135 1260 1450
060
COOLING 1575 1750 2010
COOLING
DEHUMIDIFY
1400 1400 1610
HEAT PUMP
COMFORT (50JZ Only)
1415 1575 1810
Heat Pump Efficiency
and
Cooling
pin selections deliver equal airflow
Table 18—Minimum Airflow for Reliable Electric Heater Operation (CFM)
UNIT
SIZE
024 030 036 042 048 060
50JZ 750 1025 1250 1285 1710 1800
50GL 750 750 1250 1205 1500 1800
26