Carrier 50GL 024-060 Air Conditioner User Manual


 
Table 10—50JZ with ICM FIOP Electrical Data
UNIT
SIZE 50JZ
V-PH-HZ
VOLTAGE
RANGE
COMPRESSOR
OUTDOOR
FAN
MOTOR
INDOOR
FAN
MOTOR
ELECTRIC
HEAT
SINGLE POINT
POWER SUPPLY
MIN MAX RLA LRA FLA FLA Nominal kW* FLA MCA
MAX FUSE
OR CKT. BKR.
MOCP
024 208/230–1–60 187 253 13.5 61.0 0.9 4.3
-/-
3.8/5.0
5.4/7.2
7.5/10.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
22.1/22.1
44.6/48.1
54.5/59.6
67.2/74.2
30/30
50/50
60/–
–/70
70/80
030 208/230–1–60 187 253 15.9 73.0 0.9 4.3
-/-
3.8/5.0
5.4/7.2
7.5/10.0
11.3/15.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
54.2/62.5
25.1/25.1
47.6/51.1
57.4/62.6
70.2/77.2
92.8/103.2
30/30
60/60
70/70
80/80
100/110
036 208/230–1–60 187 253 16.9 83.0 1.6 6.8
-/-
3.8/5.0
5.4/7.2
7.5/10.0
11.3/15.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
54.2/62.5
29.5/29.5
52.1/55.6
61.9/67.0
74.7/81.6
97.2/107.7
40/40
60/60
70/80
80/90
100/110
042 208/230–1–60 187 253 22.4 105.0 0.9 6.8
-/-
3.8/5.0
5.4/7.2
7.5/10.0
11.3/15.0
15.0/20.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
54.2/62.5
72.2/83.3
35.7/35.7
58.3/61.7
68.1/73.2
80.8/87.8
103.4/113.0
126.0/139.9
50/50
70/70
80/80
90/90
110/125
150/150
048 208/230–1–60 187 253 21.3 109.0 1.6 6.8
-/-
3.8/5.0
5.4/7.2
7.5/10.0
11.3/15.0
15.0/20.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
54.2/62.5
72.2/83.3
35.0/35.0
57.6/61.1
67.4/72.5
80.2/87.1
102.7/113.2
125.3/139.2
50/50
70/70
80/80
90/90
110/125
150/150
060 208/230–1–60 187 253 27.6 158.0 1.6 9.2
-/-
3.8/5.0
5.4/7.2
7.5/10.0
11.3/15.0
15.0/20.0
-/-
18.1/20.8
25.9/30.0
36.1/41.7
54.2/62.5
72.2/83.3
45.1/45.1
67.7/71.1
77.7/82.8
90.2/97.2
112.8/123.2
135.4/149.3
60/60
80/80
90/90
100/110
125/125
150/150
* Heater capacity (kW) based on heater voltage of 208-v & 240-v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly.
Refer to
Multiplication Factors
Table 23.
22