Carrier 48GP (N) 024-060 Air Conditioner User Manual


 
Table 11–48GP & 48JZ Cooling (and Heat Pump Heating-48JZ only)
Dry Coil ICM Airflow
Small Cabinet
UNIT
SIZE
CFM ADJUST
PIN SELECT
LO PIN NOM PIN HI PIN
EXTERNAL STATIC
PRESSURE RANGE
0.0–0.4 0.4–0.7 0.7–1.0 0.0–0.4 0.4–0.7 0.7–1.0 0.0–0.4 0.4–0.7 0.7–1.0
024
COOLING 745 675 835 750 690 940 880 815
COOLING
DEHUMIDIFY
675 625 675 650 600 755 730 705
HEAT PUMP
COMFORT (48JZ Only)
670 605 740 690 635 845 795 735
030
COOLING 940 860 785 1020 965 895 1185 1100 1010
COOLING
DEHUMIDIFY
820 785 735 820 800 770 955 920 880
HEAT PUMP
COMFORT (48JZ Only)
850 780 745 935 905 845 1055 1040 955
036
COOLING 1025 935 1145 1085 1005 1320 1260 1180
COOLING
DEHUMIDIFY
925 885 925 900 870 1060 1040 1010
HEAT PUMP
COMFORT (48JZ Only)
955 880 1075 990 920 1220 1180 1125
† On 48JZ Only
Heat Pump Efficiency
and
Cooling
pin selections deliver equal airflow
Table 12—48GP & 48JZ Cooling (and Heat Pump Heating-48JZ only)
Dry Coil ICM Airflow
Large Cabinet
UNIT
SIZE
CFM ADJUST
PIN SELECT
LO PIN NOM PIN HI PIN
EXTERNAL STATIC
PRESSURE RANGE
0.1–1.0 0.1–1.0 0.1–1.0
042
COOLING 1100 1225 1410
COOLING
DEHUMIDIFY
980 980 1125
HEAT PUMP
COMFORT (48JZ Only)
990 1100 1265
048
COOLING 1260 1400 1610
COOLING
DEHUMIDIFY
1120 1120 1290
HEAT PUMP
COMFORT (48JZ Only)
1135 1260 1450
060
COOLING 1575 1750 2010
COOLING
DEHUMIDIFY
1400 1400 1610
HEAT PUMP
COMFORT (48JZ Only)
1415 1575 1810
† On 48JZ Only
Heat Pump Efficiency
and
Cooling
pin selections deliver equal airflow
24