Carrier 25HCS3C Heat Pump User Manual


 
23
DETAI LED COOLING CAPACITIES (CONT.)
EVAPORATOR AIR
CONDENSER ENTERING AIR TEMPERATURES deg ˚F(˚C)
75 (23.9) 85(29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
CFM EWB
CapacityM Btuh
Total Sys-
tem KW
CapacityM Btuh
Total
System
KW
CapacityM Btuh
Total
System
KW
CapacityM Btuh
Total
System
KW
CapacityM Btuh
Total
System
KW
CapacityM Btuh
Total
System
KW
Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens
25HCS360C30 Outdoor Section With FC4DN(F,B)060 Indoor Section
1750
72 69.08 35.57 4.41 66.46 34.55 4.82 63.76 33.51 5.28 60.98 32.46 5.79 58.07 31.36 6.35 55.03 30.23 6.95
67 63.00 44.16 4.34 60.58 43.11 4.75 58.07 42.04 5.21 55.49 40.95 5.72 52.81 39.83 6.27 50.00 38.66 6.87
63 58.60 42.72 4.29 56.33 41.68 4.71 0.00 0.00 0.00 51.56 39.50 5.67 49.03 38.37 6.21 46.39 37.19 6.81
62 57.53 52.69 4.28 55.33 51.59 4.70 53.07 50.45 5.15 50.75 49.24 5.66 48.37 47.91 6.21 46.07 46.07 6.80
57 55.75 55.75 4.27 53.98 53.98 4.68 52.14 52.14 5.14 50.22 50.22 5.65 48.20 48.20 6.20 46.08 46.08 6.80
2000
72 70.29 37.22 4.50 67.57 36.18 4.92 64.76 35.13 5.38 61.88 34.07 5.89 58.86 32.96 6.44 55.72 31.81 7.05
67 64.12 46.90 4.44 61.60 45.84 4.85 59.00 44.75 5.31 56.33 43.65 5.82 53.55 42.49 6.37 50.65 41.30 6.97
63 59.68 45.29 4.39 57.32 44.23 4.80 54.88 43.13 5.26 52.36 42.01 5.76 49.74 40.85 6.31 47.02 39.64 6.90
62 58.77 56.33 4.38 56.52 55.12 4.79 54.24 53.79 5.25 52.03 52.03 5.76 49.89 49.89 6.31 47.64 47.64 6.92
57 57.93 57.93 4.37 56.04 56.04 4.79 54.08 54.08 5.25 52.04 52.04 5.76 49.89 49.89 6.31 47.64 47.64 6.92
2250
72 71.19 38.78 4.60 68.38 37.73 5.01 65.49 36.67 5.47 62.53 35.60 5.98 59.43 34.48 6.54 56.21 33.32 7.14
67 64.95 49.52 4.53 62.36 48.43 4.94 59.68 47.33 5.40 56.94 46.20 5.91 54.09 45.03 6.46 51.12 43.81 7.06
63 60.49 47.73 4.48 58.05 46.64 4.89 55.54 45.53 5.35 52.95 44.38 5.85 50.27 43.20 6.40 47.49 41.96 7.00
62 59.88 59.44 4.48 57.72 57.72 4.89 55.66 55.66 5.35 53.51 53.51 5.86 51.27 51.27 6.42 48.91 48.91 7.02
57 59.72 59.72 4.48 57.73 57.73 4.89 55.66 55.66 5.35 53.52 53.52 5.86 51.28 51.28 6.42 48.91 48.91 7.02
Cooling Indoor Model Capacity Power Furnace Model
*FC4DN(F,B)060 1.00 1.00
FK4DNB006 0.99 0.97
CSRH*6012A** 0.97 0.97 58CV(A,X)135---22
CAR**6024A** 0.98 0.98 58CV(A,X)155 ---22
CNRH*6024A** 0.97 0.97 58CV(A,X)155---22
CNRV*6024A** 0.97 0.97 58CV(A,X)155---22
CSRH*6012A** 0.98 0.97 58CV(A,X)155---22
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolatio n i s not an acceptabl e practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the sa me elevation per ARI standard 210/ 240---94. If additional tubing length and/or indoor unit is located above outdoorunit, a slight variation in capacity may occur.
{ Total and sensible capacitiesare net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F(27_C)entering airat the indoor coil. For sensible capacitiesat otherthan 80_F(27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor co i l a ir for each degree below 80_F(27_C), or add 835 Btuh (245 kW) per1000 CF M (480 L/S) of indoor coil air per degree above 80_F(27_C).
** System kwis total of indoor and outdoorunit kilowatts.
{{ At TVA rating indoor condition(75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
EWB — Entering Wet Bulb
25HCS3C