MODEL NUMBER NOMENCLATURE
12 3 4 5 6 78 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
25 H C S 3 36 C 0 0 3 0
Product
Series
Product
Family
Tier
Major
Series
SEER
Cooling
Capacity
Variations Open Open Voltage
Minor
Series
25 = HP H = RES HP C=Comfort S = R---22 3=13 SEER C = Coastal
0=Not
Defined
0=Not
Defined
3=208/230---1
0, 1, 2...
REGISTERED
ISO 9001:2000
This product has beendesigned an dmanufactured to
meet Energy Star® criteriaforenergyefficiency when
matchedwithappropriatecoil components. However,
proper refrigerant charge andproper airflow a recritical
toachieveratedcapacityandefficiency. Installationof
thisproductshouldfollowallmanufacturingrefrigerant
chargingandairflowinstructions. Failuretoconfirm
properc hargean d airflowmayreduceen ergy
efficiencya ndshort en equipmentlife.
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
Maximum SEER Rating 15.0 15.0 13.1 13.5 14.0 14.0 13.0
Scroll Compressor X X X X X X X
Louvered Coil Guard X X X X X X X
FieldInstalledFilterDrier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
High Pressure Switch X X X X X X X
Loss of Charge Pressure Switch X X X X X X X
X=Standard
25HCS3C