PERFORMANCE DATA (cont)
COMBINATION RATINGS*
UNIT 569D072
LEGEND
*Combinations on this page are E
NERGY STAR ® compliant.
569D072/524A-C072 WITH HIGH-CAPACITY 4-ROW COIL
Temp (F)
Air Entering
Condenser
(Edb)
Evaporator Air — Cfm
1800 2400 3000
Evaporator Air — Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
80
TC 66.0 68.6 74.3 80.7 72.0 72.6 77.7 84.1 76.2 76.2 79.9 86.2
SHC 66.0 60.9 51.0 40.8 72.0 70.5 58.6 45.5 76.2 76.2 65.7 50.0
kW 4.45 4.49 4.60 4.71 4.55 4.57 4.66 4.78 4.63 4.63 4.70 4.82
85
TC 65.1 67.5 73.1 79.3 71.0 71.4 76.3 82.6 75.0 75.1 78.5 84.6
SHC 65.1 60.3 50.5 40.3 71.0 69.8 58.1 45.0 75.0 75.1 65.2 49.5
kW 4.72 4.76 4.87 4.99 4.83 4.84 4.93 5.05 4.91 4.90 4.97 5.09
95
TC 63.3 65.2 70.6 76.7 68.9 69.1 73.6 79.7 72.8 72.8 75.7 81.6
SHC 63.3 59.2 49.4 39.3 68.9 68.3 57.0 44.0 72.8 72.8 64.0 48.5
kW 5.26 5.30 5.41 5.53 5.37 5.38 5.47 5.60 5.45 5.45 5.51 5.64
100
TC 62.3 64.0 69.2 75.2 67.7 67.9 72.2 78.2 71.5 71.5 74.2 80.0
SHC 62.3 58.6 48.9 38.8 67.7 67.4 56.5 43.5 71.5 71.5 63.4 47.9
kW 5.57 5.61 5.71 5.84 5.68 5.68 5.78 5.90 5.76 5.76 5.82 5.95
105
TC 61.3 62.8 67.9 73.8 66.6 66.7 70.7 76.6 70.3 70.3 72.7 78.4
SHC 61.3 58.0 48.3 38.2 66.6 66.6 55.9 42.9 70.3 70.3 62.8 47.4
kW 5.88 5.91 6.02 6.15 5.99 5.99 6.08 6.21 6.07 6.08 6.12 6.26
115
TC 59.3 60.5 65.2 70.9 64.4 64.3 67.8 73.5 67.9 67.9 69.7 75.2
SHC 59.3 56.8 47.2 37.2 64.4 64.3 54.8 41.9 67.9 67.9 61.6 46.4
kW 6.51 6.53 6.63 6.77 6.61 6.61 6.70 6.83 6.69 6.70 6.74 6.88
569D072/524A-B072 WITH STANDARD 3-ROW COIL
Temp (F)
Air Entering
Condenser
(Edb)
Evaporator Air — Cfm
1800 2400 3000
Evaporator Air — Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
80
TC 63.4 66.1 71.7 77.8 69.0 69.8 74.9 81.1 72.9 72.9 76.9 83.1
SHC 63.4 58.4 49.0 39.2 69.0 67.2 56.0 43.6 72.9 72.9 62.5 47.6
kW 4.40 4.45 4.55 4.66 4.50 4.52 4.60 4.72 4.57 4.57 4.64 4.76
85
TC 62.5 65.1 70.5 76.6 68.0 68.7 73.6 79.7 71.9 71.9 75.6 81.7
SHC 62.5 57.9 48.5 38.8 68.0 66.6 55.5 43.1 71.9 71.9 62.0 47.2
kW 4.67 4.72 4.82 4.93 4.77 4.79 4.88 4.99 4.84 4.84 4.91 5.03
95
TC 60.8 62.9 68.2 74.1 66.1 66.5 71.1 77.0 69.7 69.8 73.1 78.9
SHC 60.8 56.8 47.5 37.9 66.1 65.2 54.6 42.2 69.7 69.8 60.9 46.2
kW 5.22 5.26 5.36 5.48 5.32 5.33 5.42 5.54 5.39 5.39 5.46 5.58
100
TC 59.9 61.8 67.0 72.8 65.1 65.4 69.8 75.6 68.6 68.6 71.7 77.4
SHC 59.9 56.3 47.0 37.4 65.1 64.4 54.0 41.7 68.6 68.6 60.4 45.7
kW 5.53 5.56 5.67 5.79 5.63 5.63 5.73 5.85 5.70 5.70 5.76 5.89
105
TC 59.0 60.7 65.7 71.4 64.0 64.2 68.5 74.1 67.5 67.5 70.3 75.9
SHC 59.0 55.7 46.5 36.9 64.0 63.7 53.5 41.2 67.5 67.5 59.8 45.2
kW 5.84 5.87 5.98 6.10 5.94 5.94 6.03 6.16 6.01 6.01 6.07 6.20
115
TC 57.1 58.4 63.3 68.7 61.9 61.9 65.8 71.3 65.2 65.2 67.4 72.9
SHC 57.1 54.6 45.5 35.9 61.9 61.9 52.4 40.2 65.2 65.2 58.7 44.2
kW 6.46 6.48 6.59 6.72 6.57 6.56 6.65 6.78 6.64 6.63 6.68 6.82
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW—Compressor Motor Power Input
SHC Sensible Heat Capacity (1000 Btuh) Gross
TC Total Capacity (1000 Btuh) Gross
50TFQ004-012