31
HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOORAIR
OUTDOOR COILENTERINGAIRTEMPERATURES d egF
--3 7 17 27 37 47 57 67
EDB CFM
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
CapacityMBtuh
Total
System
KW†
Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ* Total Integ*
265ANA060--BOutdoorSectionWithFX4CNF 060IndoorSec tion
65
1750 25.04 23.04 3.66 30.87 28.37 3.82 37.09 33.82 3.99 43.79 38.89 4.18 51.53 46.90 4.41 59.82 59.82 4.61 68.25 68.25 4.88 76.95 76.95 5.17
2000 25.48 23.44 3.69 31.34 28.80 3.84 37.58 34.27 4.00 44.35 39.39 4.17 52.32 47.61 4.35 60.19 60.19 4.54 68.33 68.33 4.77 72.60 72.60 4.88
2250 25.87 23.80 3.74 31.76 29.18 3.88 38.03 34.67 4.02 44.84 39.82 4.18 52.89 48.13 4.34 60.29 60.29 4.51 66.89 66.89 4.68 68.93 68.93 4.71
70
1750 24.33 22.39 3.82 30.20 27.76 3.99 36.48 33.26 4.18 43.16 38.33 4.39 50.61 46.05 4.62 59.08 59.08 4.83 67.48 67.48 5.11 76.32 76.32 5.42
2000 24.77 22.79 3.86 30.68 28.20 4.02 36.99 33.72 4.19 43.72 38.83 4.37 51.39 46.77 4.58 59.50 59.50 4.76 67.66 67.66 5.00 73.14 73.14 5.16
2250 25.17 23.16 3.91 31.11 28.59 4.05 37.43 34.13 4.21 44.21 39.27 4.38 52.04 47.36 4.55 59.73 59.73 4.73 67.52 67.52 4.94 69.87 69.87 4.98
75
1750 23.57 21.68 3.99 29.51 27.12 4.18 35.83 32.67 4.38 42.51 37.75 4.59 49.79 45.31 4.83 58.34 58.34 5.06 66.67 66.67 5.35 75.53 75.53 5.68
2000 24.01 22.09 4.03 29.99 27.56 4.20 36.35 33.14 4.38 43.07 38.26 4.58 50.52 45.97 4.79 58.80 58.80 4.99 66.99 66.99 5.24 73.35 73.35 5.44
2250 24.41 22.46 4.08 30.42 27.95 4.23 36.81 33.56 4.40 43.57 38.70 4.58 51.16 46.56 4.77 59.10 59.10 4.95 67.03 67.03 5.18 70.50 70.50 5.26
HeatingIndoor Model Capacity Power Furnace Model
*FX4CN(B,F)060 1.00 1.00
FE4ANB006 0.99 1.00
FV4BNB006 0.99 1.00
FY4ANB060 1.01 1.05
CAP**6021A** 0.99 1.04
CAP**6024A** 1.01 1.04
CNPH*6024A** 1.01 1.04
CNPV*6024A** 1.01 1.04
CSPH*6012A** 1.01 1.02
CAP**6021A** 0.99 1.04 315(A,J)AV060110
CNPH*6024A** 0.98 1.05 315(A,J)AV060110
CSPH*6012A** 0.98 1.02 315(A,J)AV060110
CAP**6024A** 0.99 1.04 315(A,J)AV066135
CNPH*6024A** 0.99 1.05 315(A,J)AV066135
CNPV*6024A** 0.99 1.05 315(A,J)AV066135
CSPH*6012A** 0.98 1.01 315(A,J)AV066135
CAP**6024A** 0.98 1.02 315(A,J)AV066155
CNPH*6024A** 0.99 1.04 315(A,J)AV066155
CNPV*6024A** 0.99 1.04 315(A,J)AV066155
CSPH*6012A** 0.98 1.00 315(A,J)AV066155
NOTE: When the required data falls between the publis hed data, interpolation may be performed. Extrapolati on is not an acceptab le prac tice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
EDB —EnteringDryBulb
265A