UnitSize
--- Series
IndoorModel
Cooling
Capacity
ARIStand ard Ratings
Cooling Heating
Furnace M odel
Factory
Enhance
Standard
Rating
SEER
TDR
EER
HighTemp Low Temp
HSPF
E
Capacity
E
COP
H
Capacity
H
COP
048--B
CSPH*4812A** 47,000 TDR&TXV 14.00 12.00 47,000 3.66 29,800 2.54 8.2 315(A,J)AV048090
CSPH*4812A** 47,000 TDR&TXV 14.50 12.00 47,000 3.66 29,800 2.54 8.2 315(A,J)AV060110
CSPH*4812A** 47,500 TDR&TXV 14.50 12.00 47,000 3.70 29,600 2.56 8.2 315(A,J)AV066135
CSPH*4812A** 47,500 TDR&TXV 15.00 12.50 47,000 3.72 29,600 2.58 8.2 315(A,J)AV066155
CSPH*4812A** 47,000 TDR&TXV 14.00 12.00 47,000 3.62 29,800 2.52 8.2 355AAV060080
CSPH*4812A** 47,000 TDR&TXV 14.50 12.00 47,000 3.64 29,800 2.52 8.2 355AAV060100
CSPH*4812A** 47,000 TDR&TXV 14.50 12.00 47,000 3.64 29,800 2.54 8.2 355AAV060120
CSPH*4812A** 48,000 TXV 14.00 11.50 48,500 3.72 30,600 2.54 8.3
CSPH*6012A** 48,000 TDR&TXV 14.50 12.00 47,000 3.72 29,800 2.58 8.2 315(A,J)AV048090
CSPH*6012A** 48,000 TDR&TXV 14.50 12.00 47,000 3.74 29,600 2.58 8.3 315(A,J)AV060110
CSPH*6012A** 48,000 TDR&TXV 15.00 12.50 47,000 3.78 29,600 2.60 8.3 315(A,J)AV066135
CSPH*6012A** 48,000 TDR&TXV 15.00 12.50 47,000 3.80 29,400 2.62 8.4 315(A,J)AV066155
CSPH*6012A** 48,000 TDR&TXV 14.50 12.00 47,000 3.70 29,800 2.56 8.2 355AAV060080
CSPH*6012A** 48,000 TDR&TXV 14.50 12.00 47,000 3.72 29,800 2.56 8.2 355AAV060100
CSPH*6012A** 48,000 TDR&TXV 14.50 12.00 47,000 3.70 29,800 2.56 8.2 355AAV060120
CSPH*6012A** 48,000 TXV 14.00 12.00 48,500 3.78 30,800 2.56 8.3
060--B
*FX4CN(B,F)060 60,000 TDR&TXV 14.00 11.50 59,500 3.70 37,000 2.60 8.4
FE4ANB006 59,500 TDR&TXV 14.00 11.50 59,000 3.68 36,000 2.62 8.3
FV4BNB006 59,500 TDR&TXV 14.00 11.50 59,000 3.68 36,000 2.62 8.3
FY4ANB060 59,500 TDR&TXV 13.00 10.80 60,000 3.56 37,800 2.50 8.0
CAP**6021A** 58,000 TDR&TXV 13.50 11.20 59,000 3.52 36,400 2.52 8.0 315(A,J)AV060110
CAP**6021A** 58,000 TXV 13.50 11.20 59,000 3.52 36,600 2.52 7.9
CAP**6024A** 58,500 TDR&TXV 13.50 11.20 59,000 3.54 36,200 2.54 8.0 315(A,J)AV066135
CAP**6024A** 59,000 TDR&TXV 13.50 11.20 58,500 3.58 36,000 2.56 8.0 315(A,J)AV066155
CAP**6024A** 59,000 TXV 13.20 11.00 60,000 3.58 37,200 2.54 8.0
CNPH*6024A** 58,500 TDR&TXV 13.50 11.20 58,500 3.48 36,200 2.52 7.9 315(A,J)AV060110
CNPH*6024A** 58,500 TDR&TXV 13.50 11.20 59,000 3.52 36,000 2.54 7.9 315(A,J)AV066135
CNPH*6024A** 58,500 TDR&TXV 13.50 11.20 59,000 3.54 36,000 2.56 8.0 315(A,J)AV066155
CNPH*6024A** 59,000 TXV 13.20 11.00 60,000 3.58 37,000 2.54 8.0
CNPV*6024A** 58,500 TDR&TXV 13.50 11.20 59,000 3.52 36,000 2.54 7.9 315(A,J)AV066135
CNPV*6024A** 58,500 TDR&TXV 13.50 11.20 59,000 3.54 36,000 2.56 8.0 315(A,J)AV066155
CNPV*6024A** 59,000 TXV 13.20 11.00 60,000 3.58 37,000 2.54 8.0
CSPH*6012A** 58,500 TDR&TXV 13.50 11.20 58,500 3.58 36,400 2.54 8.0 315(A,J)AV060110
CSPH*6012A** 58,500 TDR&TXV 13.50 11.20 58,500 3.60 36,000 2.56 8.0 315(A,J)AV066135
CSPH*6012A** 59,000 TDR&TXV 13.50 11.20 58,500 3.64 36,000 2.58 8.0 315(A,J)AV066155
CSPH*6012A** 58,500 TXV 13.20 11.00 60,000 3.64 37,200 2.56 8.0
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F(27_C) db 67_F(19_C) wb indoor entering air temperature and 95_F(35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 47_F(8_C) db 43˚F(6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 17_F(9_C) db 15˚F(10_C) wb air entering outdoor unit.
SEER — Seasonal Energy Efficiency Ratio
COP — Coefficient of Performance
TDR — Time---Delay Relay
HSPF — Heating Seasonal Performance Factor
EER — Energy Efficiency Ratio
265A