Bryant 213A Heat Pump User Manual


 
31
HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOORAIR
OUTDOORCOILENTERINGAIR TEMPERATURESdegF
---3 7 17 27 37 47 57 67
EDB CFM
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Capacity
MBtuh
Total
Sys-
tem
KW†
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
Total
In-
teg*
213ANA060---AOutdoor SectionWith FY4ANF060IndoorSection
65
1750 25.07 23.07 3.86 30.90 28.40 4.00 37.17 33.89 4.16 43.81 38.91 4.34 51.11 46.51 4.54 59.85 59.85 4.79 68.95 68.95 5.02 78.00 78.00 5.31
2000 25.62 23.57 3.93 31.49 28.94 4.06 37.79 34.45 4.20 44.47 39.50 4.36 51.96 47.28 4.54 60.88 60.88 4.74 69.47 69.47 4.95 78.33 78.33 5.20
2250 26.13 24.04 4.01 32.03 29.44 4.13 38.34 34.96 4.26 45.07 40.03 4.40 52.72 47.97 4.57 61.49 61.49 4.73 69.75 69.75 4.92 77.76 77.76 5.13
70
1750 24.34 22.40 4.03 30.22 27.77 4.19 36.54 33.32 4.36 43.21 38.37 4.55 50.41 45.87 4.76 58.98 58.98 5.03 68.13 68.13 5.26 77.06 77.06 5.56
2000 24.89 22.90 4.10 30.80 28.30 4.24 37.17 33.89 4.40 43.87 38.96 4.57 51.17 46.57 4.75 60.00 60.00 4.97 68.71 68.71 5.18 77.50 77.50 5.44
2250 25.40 23.37 4.18 31.34 28.80 4.31 37.72 34.39 4.45 44.46 39.49 4.60 51.85 47.19 4.77 60.72 60.72 4.95 69.06 69.06 5.15 77.77 77.77 5.39
75
1750 23.57 21.68 4.21 29.50 27.11 4.38 35.86 32.70 4.57 42.56 37.80 4.77 49.72 45.25 4.99 57.81 57.81 5.26 67.28 67.28 5.51 76.15 76.15 5.82
2000 24.12 22.19 4.29 30.09 27.65 4.44 36.50 33.28 4.60 43.24 38.40 4.78 50.48 45.93 4.98 58.94 58.94 5.21 67.93 67.93 5.43 76.69 76.69 5.70
2250 24.63 22.66 4.37 30.63 28.15 4.51 37.07 33.80 4.66 43.83 38.93 4.82 51.15 46.54 5.00 59.80 59.80 5.19 68.35 68.35 5.40 76.95 76.95 5.64
HeatingIndoor
Model
Capacity Power FurnaceModel
*FY4ANB060 1.00 1.00
FV4BNB006 0.98 0.94
FX4CN(B,F)060 0.98 0.94
CAP**6021A** 0.97 1.00
CAP**6024A** 0.98 0.99
CNPH*6024A** 0.98 0.99
CNPV*6024A** 0.98 0.99
CSPH*6012A** 0.98 0.98
HeatingIndoor
Model
Capacity Power FurnaceModel
CAP**6021A** 0.94 0.98 315(A,J)AV060110
CNPH*6024A** 0.96 1.00 315(A,J)AV060110
CSPH*6012A** 0.96 0.98 315(A,J)AV060110
CAP**6024A** 0.96 0.99 315(A,J)AV066135
CNPH*6024A** 0.95 0.99 315(A,J)AV066135
CNPV*6024A** 0.95 0.99 315(A,J)AV066135
CSPH*6012A** 0.96 0.98 315(A,J)AV066135
CAP**6024A** 0.96 0.98 315(A,J)AV066155
CNPH*6024A** 0.95 0.98 315(A,J)AV066155
CNPV*6024A** 0.95 0.98 315(A,J)AV066155
CSPH*6012A** 0.96 0.97 315(A,J)AV066155
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB Entering Dry Bulb
213A