Bryant 213A Heat Pump User Manual


 
17
COMBINATION RATINGS CONTINUED
Unit
Size ---
Series
Indoor Model
Cooling
Capacity
ARI Standard Ratings
Cooling Heating
Furnace Model
Factory
Enhance
Standard
Rating
SEER
TDR
EER
High Temp Low Temp
HSPF
E
Capacity
E
COP
H
Capacity
H
COP
048---A
CNPH*4821A** 45,000 TXV 13.00 10.80 49,000 3.68 30,400 2.60 8.4
CNPH*6024A** 46,500 TDR&TXV 14.00 11.70 46,000 3.68 29,600 2.64 8.4 315(A,J)AV048090
CNPH*6024A** 46,500 TDR&TXV 14.00 11.70 46,000 3.70 29,600 2.66 8.5 315(A,J)AV060110
CNPH*6024A** 46,500 TDR&TXV 14.00 12.00 46,000 3.74 29,400 2.68 8.5 315(A,J)AV066135
CNPH*6024A** 47,000 TDR&TXV 14.00 12.00 46,000 3.76 29,400 2.68 8.6 315(A,J)AV066155
CNPH*6024A** 46,500 TDR&TXV 14.00 11.50 46,000 3.66 29,800 2.62 8.4 355AAV060080
CNPH*6024A** 46,500 TDR&TXV 14.00 11.70 46,000 3.68 29,600 2.64 8.4 355AAV060100
CNPH*6024A** 46,500 TDR&TXV 14.00 11.70 46,000 3.68 29,600 2.64 8.4 355AAV060120
CNPH*6024A** 47,000 TXV 13.00 10.80 45,000 3.66 30,600 2.62 8.5
CNPV*4821A** 45,500 TDR&TXV 14.00 11.50 48,000 3.64 29,600 2.62 8.4 315(A,J)AV060110
CNPV*4821A** 45,500 TDR&TXV 14.00 11.50 48,500 3.60 29,600 2.60 8.3 355AAV060080
CNPV*4821A** 45,500 TDR&TXV 14.00 11.50 48,000 3.62 29,600 2.60 8.3 355AAV060100
CNPV*4821A** 46,000 TXV 13.00 10.80 49,000 3.68 30,400 2.60 8.4
CNPV*4824A** 45,500 TDR&TXV 14.00 11.70 48,000 3.68 29,400 2.64 8.4 315(A,J)AV066135
CNPV*4824A** 46,000 TDR&TXV 14.00 11.50 48,000 3.70 29,400 2.66 8.5 315(A,J)AV066155
CNPV*4824A** 45,500 TDR&TXV 14.00 11.50 48,000 3.62 29,600 2.60 8.3 355AAV060120
CNPV*4824A** 46,000 TXV 13.00 10.80 49,000 3.68 30,400 2.60 8.4
CNPV*6024A** 46,500 TDR&TXV 14.00 12.00 46,000 3.74 29,400 2.68 8.5 315(A,J)AV066135
CNPV*6024A** 47,000 TDR&TXV 14.00 12.00 46,000 3.76 29,400 2.68 8.6 315(A,J)AV066155
CNPV*6024A** 46,500 TDR&TXV 14.00 11.70 46,000 3.68 29,600 2.64 8.4 355AAV060120
CNPV*6024A** 47,000 TXV 13.00 10.80 45,000 3.66 30,600 2.62 8.5
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.50 48,000 3.68 29,800 2.62 8.4 315(A,J)AV048090
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.50 48,000 3.70 29,600 2.62 8.4 315(A,J)AV060110
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.70 48,000 3.72 29,600 2.64 8.5 315(A,J)AV066135
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.70 48,000 3.76 29,400 2.66 8.6 315(A,J)AV066155
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.50 48,500 3.66 29,800 2.60 8.4 355AAV060080
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.50 48,000 3.68 29,800 2.62 8.4 355AAV060100
CSPH*4812A* * 45,500 TDR&TXV 14.00 11.50 48,000 3.66 29,600 2.62 8.4 355AAV060120
CSPH*4812A* * 46,000 TXV 13.00 10.80 49,000 3.72 30,600 2.62 8.5
CSPH*6012A* * 46,500 TDR&TXV 14.00 11.70 46,000 3.74 29,600 2.66 8.5 315(A,J)AV048090
CSPH*6012A* * 47,000 TDR&TXV 14.00 11.70 46,000 3.76 29,600 2.68 8.6 315(A,J)AV060110
CSPH*6012A* * 47,000 TDR&TXV 14.00 12.00 46,000 3.78 29,600 2.70 8.6 315(A,J)AV066135
CSPH*6012A* * 47,000 TDR&TXV 14.00 12.00 46,000 3.80 29,400 2.70 8.7 315(A,J)AV066155
CSPH*6012A* * 46,500 TDR&TXV 14.00 11.70 46,000 3.70 29,800 2.64 8.5 355AAV060080
CSPH*6012A* * 46,500 TDR&TXV 14.00 11.70 46,000 3.72 29,800 2.66 8.5 355AAV060100
CSPH*6012A* * 46,500 TDR&TXV 14.00 11.70 46,000 3.72 29,600 2.66 8.5 355AAV060120
CSPH*6012A* * 47,000 TXV 13.00 10.80 45,000 3.68 30,600 2.64 8.5
060---A
*FY4ANB060 59,500 TDR&TXV 13.00 10.8 60,000 3.62 38,500 2.56 8.0
FV4BNB006 60,000 TDR&TXV 14.00 11.50 58,500 3.74 36,200 2.68 8.2
FX4CN(B,F)060 60,000 TDR&TXV 14.00 12.00 58,500 3.74 36,200 2.68 8.3
CAP**6021A** 58,000 TDR&TXV 13.50 11.20 56,500 3.48 36,000 2.52 7.8 315(A,J)AV060110
CAP**6021A** 59,000 TXV 13.00 10.80 58,000 3.48 36,400 2.52 7.8
CAP**6024A** 59,000 TDR&TXV 13.50 11.50 57,500 3.50 35,800 2.54 7.8 315(A,J)AV066135
CAP**6024A** 59,000 TDR&TXV 14.00 11.50 57,500 3.54 35,800 2.56 7.9 315(A,J)AV066155
CAP**6024A** 60,000 TXV 13.00 10.80 59,000 3.60 37,000 2.54 8.0
CNPH*6024A** 58,500 TDR&TXV 13.50 11.20 57,500 3.46 36,000 2.52 7.7 315(A,J)AV060110
CNPH*6024A** 58,500 TDR&TXV 13.50 11.20 57,000 3.48 35,800 2.54 7.8 315(A,J)AV066135
CNPH*6024A** 59,000 TDR&TXV 14.00 11.50 57,000 3.52 35,800 2.56 7.8 315(A,J)AV066155
CNPH*6024A** 59,500 TXV 13.00 10.80 58,500 3.54 37,600 2.60 8.0
CNPV*6024A** 58,500 TDR&TXV 13.50 11.20 57,000 3.48 35,800 2.54 7.8 315(A,J)AV066135
CNPV*6024A** 59,000 TDR&TXV 14.00 11.50 57,000 3.52 35,800 2.56 7.8 315(A,J)AV066155
CNPV*6024A** 59,500 TXV 13.00 10.80 58,500 3.54 36,800 2.54 7.9
CSPH*6012A* * 59,000 TDR&TXV 13.50 11.20 57,500 3.52 36,000 2.54 7.8 315(A,J)AV060110
CSPH*6012A* * 59,000 TDR&TXV 14.00 11.50 57,500 3.56 35,800 2.56 7.9 315(A,J)AV066135
CSPH*6012A* * 59,000 TDR&TXV 14.00 11.50 57,500 3.58 35,800 2.58 7.9 315(A,J)AV066155
CSPH*6012A* * 60,000 TXV 13.00 10.80 59,000 3.62 37,000 2.56 8.0
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F(27_C) db 67_F(19_C) wb indoor entering air temperature and 95_F(35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 47_F(8_C) db 43˚F(6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 17_F(±9_C) db 15˚F(±10_C) wb air entering outdoor unit.
SEER Seasonal Energy Efficiency Ratio
COP Coefficient of Performance
TDR Time---Delay Relay
HSPF Heating Seasonal Performance Factor
EER Energy Efficiency Ratio
213A