Brother 342Fi Sewing Machine User Manual


 
11. CHANGING SPECIAL FUNCTION AND USING THE MEMORY SWITCHES
BAS-341F, 342F
47
Memory switches (10 - 1F)
Switch No. When ON
memo-10 Milling device can be used (available as an option)
memo-11 Bobbin thread counter and production counter are adjusted when thread is trimmed.
memo-12
Work clamp is lowered by pressing work clamp first stage switch twice, without using work clamp
second stage switch. When DIP switch A-2 is ON, work clamp lowers in the order right left;
when OFF, work clamp lowers in the order left right. Order is opposite when rising.
memo-13
When work clamp is lowered, the starting switch causes locking; if the switch is released before
locking, the work clamp rises
When DIP switch A - 2 is ON, work clamp lowers in the order right left; when OFF, work clamp
lowers in the order left right. Order is opposite when rising
memo-14 Needle up error detected.
memo-15
ON when machine is equipped with signal tower indicator. (This indicator is available by special
order.)
memo-16 ON when machine is equipped with thread nipper. (Thread nipper is available by special order.)
memo-17 ON when machine is equipped with reset switch. (Reset switch is available by special order.)
memo-18
Starting switch causes work clamp to drop in order right left forward control is in the same
order as starting, and for backward control the work clamp rises in the order left right using
work clamp first stage switch (when DIP switch A-2 is ON). When OFF, the left and right orders are
reversed.
memo-19
Produces two work clamp signal outputs (right and left work clamp) so that a two-position air valve
can be used. (Two-position air valve is available by special order.)
memo-1A
When using a triple pedal (DIP switch B-7 is also ON), the right is used exclusively to detect the
home position. If DIP switch A-7 is OFF, the left pedal causes left and right work clamps to be raised
and lowered simultaneously. If ON, the left pedal causes the left work clamp to be raised and
lowered, and the right work clamp lowers when starting pedal to sew.
memo-1b KE430C single foot pedal can be used. DIP switch A-7 is ON.
memo-1c Bobbin thread counter is decremented at the start of sewing.
memo-1d
When using an air pressure drop detection switch. (This detection switch is available by special
order.)
memo-1E
Changes the split number automatically by using an external switch. (Use option connector P3 on
the operation panel.)
memo-1F
Program number is changed automatically by using outside switch. (Use optional connector P3 on
the operation panel.)