Broan ERV90HC Air Cleaner User Manual


 
8. CONNECTING THE DRAIN (HRV UNITS ONLY)
VO0091
VO0093
VO0092
To drain
In order to keep the drain pan intact, hand
tighten the 2 plastic drain fittings to the unit
door using the gaskets and nuts as shown.
Cut 2 sections of plastic tubing, about 12”
(305 mm) long and attach them to each
drain fitting. Join the 2 short sections to the
«T» junction and main tube as shown.
Make a water trap loop in the tube to prevent
the unit from drawing unpleasant odors from
the drain source. Make sure this loop is
situated BELOW the «T» as shown.This will
prevent water from being drawn back up into
the unit in case of negative pressure. Run
the tube to the floor drain or to an alternative
drain pipe or pail. Be sure there is a slight
slope for the run-off.
Tie-wrap
From the inner side of the unit door, using the
provided drain tube, punch out both drain
holes (A).
VD0181
A
- 22 -