Bradford-White Corp MITW -12 / -15 Water Heater User Manual


 
TTW1 Universal Service
Replacement Blower
MITW -10 Series
Page 6
Step 1. Unplug water heater from wall outlet.
Step 2. Detach blower wire harness from receptacle
located in the jacket head.
Step 3. Disconnect the vent pipe and adapter that are
connected to the outlet of the blower.
Remove power
cord from outlet.
Unplug blower harness from
jacket head receptacle.
Unscrew both clamps that
hold the adapter to the
blower and vent pipe.
Note: This set of instructions is for the following model numbers: MITW40L*LN10,
MITW40L*CX10, MITW50L*LN10, and MITW50L*CX10.
Note: The following parts are required to convert the model numbers shown above:
Template, Flue Restrictor, Screws, Wire Harness MITW-10 Series, Universal Blower,
Wire Nuts, and 2" Exhaust Adapter / Vent Terminal Kit. Please refer to the Kit
Components page (Page 3) for a picture of each item.