Step 9.
c.) Replace the intake boot back onto the
blower. If it is necessary, the cable, or
zip, tie can be removed from the boot
to allow for easier assembly.
Step 10. Now that the universal blower is properly
modified for a M1TW series water heater,
the blower can be properly positioned and
secured on top of the water heater. To
place the blower on the water heater, feed
the blower from around the backside of
the water connections. Secure the
universal blower using (3) screws, P/N
239-44113-00, provided with the kit, into
the pre-existing holes used to fasten the
original blower. Tighten them using a ¼”
nut driver.
Step 11. With the blower securely fastened to the
water heater, the blower wire harness
cord sets can now be re-connected to the
blower housing.
Secure (3) blower screws.
Remove cable tie if boot
will not go onto rear of
blower easily.
Replace boot on
rear of blower.
Boot back
in place.
Plug blower harness cord sets
into blower housing receptacles.