Bradford-White Corp IGI-180C Water Heater User Manual


 
WARNING
When the Water Heater or remotely located Main Control is used in public use applications, it shall
be installed in a location where it cannot be adjusted by the public (i.e., a maintenance room or
manager’s office). Unauthorized adjustments may result in scalding conditions.
NOTICE
Only one remote control can be connected to one Commercial EVERHOT® model water heater
(i.e., Installations with two controls will not function properly).
In most situations, the Main Control on the water heater will suit the customer’s needs and reduce the
installation time required. If a remotely located temperature control is desired, a commercial Main Control
(239-44510-00) may be purchased from your supplier. When deciding on the best location for the remote
control, please consider the following items:
1. Place the control out of reach of small children.
2. Avoid locations that may allow adjustment by unauthorized personnel (see above warning).
3. Avoid locations where the control will become hot, such as over the stove, near the oven, or other
heat sources.
4. Avoid direct sunlight. (The digital readout can be difficult to read in direct sunlight).
5. Avoid areas where the remote can be splashed with cooking water, oil, or sauce.
6. The remote control operates with low voltage, 12 volts DC.
Remote Main Control Installation (Optional):
Follow the same control installation procedure as outlined under “Temperature Control Installation” for
residential models. The only exception is that only one remote temperature control can be installed.
The wiring for the Main Control on the water heater must be disconnected and the remote Main
Control wiring connected on the same control terminals.
WARNING
Do not attempt to connect the remote controls with the power on to the water heater. There is 120 volt
terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must be
performed by a qualified installer.
38