plumbing system to the house. All soldering materials and piping must be compatible with
potable water. Unions should be installed on both the hot and cold water lines for future servicing
and disconnection of the water heater. Install a shut-off valve in the cold water supply line.
2. In order to service the water heater in the event the heat exchanger needs to be flushed of lime
deposits, tee fittings with shut off valves and service connections to hoses should be installed.
Also install a shut off valve to the hot water supply to isolate the service tee fittings. A plumbing
installation kit, which includes these fittings and a pressure relief valve, is available from your
supplier. Refer to the piping diagrams (fig. 1-4) in Section V, “Water Connections”.
3. Install a pressure relief valve on a tee connection from the hot water outlet piping from the water
heater. Refer to the piping diagrams (fig. 1-4) and pressure relief valve warning in Section V,
“Water Connections”.
4. In cold climates where piping can freeze during an extended power failure, drain solenoid valves
should be installed on the cold and hot water supply lines to allow water to drain from the water
heater when power is interrupted. Refer to the piping diagram (fig. 3) “Recommended Piping for
Power Failure Freeze Protection” in Section V and contact your Bradford White dealer if
assistance is needed.
5. If this water heater is installed in a closed water supply system, such as the one having a back-
flow preventer in the cold water supply, provisions must be made to control thermal expansion.
DO NOT operate this water heater in a closed system without provisions for controlling thermal
expansion. Warranties do not cover damages from thermal expansions such as pressure bulges
and/or deformities. Your water supplier or local plumbing inspector should be contacted on how
to control this situation.
6. Purge the cold water line prior to connecting to the water heater to remove debris. Debris will
clog the mesh strainer of the inlet filter. The inlet strainer prevents debris from damaging the flow
sensor or clogging the coil. It may need to be cleaned periodically and should be cleaned after
the initial operation. DO NOT operate the water heater without the filter in place.
7. After installation of the water lines, open the main water supply valve and fill the water heater.
While the water heater is filling, open several hot water faucets to allow air to escape from the
water system. When a steady stream of water flows through the faucets, close them and check
all water connections for possible leaks.
8. This water heater may also be connected to a circulating pump or storage tank for increased flow
capacity during high demand periods. Refer to the suggested piping diagrams (fig. 2 & 4) in
Section V to be used as a guide.
9. Commercial installations may require more than one water heater piped together in a manifold to
supply enough capacity for high temperature and high water flow applications. Special controls
are available from your Bradford White supplier for operating more than one water heater
together. These controls stage the operation of the water heaters for the flow rates and control
the amount of flow through each water heater. Order part# 239-44511-00 for the electronic
manifold control for the first and second water heater and part# 239-44512-00 for the wiring
harness for each additional water heater to be controlled. Instructions are included with these
parts. Use the piping diagram in figure 4 in Section V as a guide.
NOTICE
Take care when using pipe dope or Teflon tape to avoid clogging the inlet screen and water flow
sensor. Wipe off excess pipe dope from threads before connecting to the water heater.
Commercial dishwashers will require either more than one water heater, or a storage tank to supply a
sufficient volume of hot water.