Bradford-White Corp EF Water Heater User Manual


 
13
3. If the water heater is installed as a direct vent (outside air piped directly to the water heater), then additional opening, other
than the opening for the air intake, are not required. However, adequate ventilation air must be provided in all cases to
prevent increased room temperature.
CHEMICAL VAPOR CORROSION
Corrosion of the flue ways and vent system will occur if air for combustion contains certain chemical vapors. Such corrosion
may result in poor combustion and create a risk of asphyxiation, as well as reducing the life of the water heater. Spray can
propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals, calcium and sodium
chloride, waxes and process chemicals are corrosive. Products of this sort should not be stored near the water heater or outside
by the air intake (if applicable).
TYPICAL INSTALLATION ILLUSTRATION
CAUTION
If the building cold water supply has a back-flow preventer, check valve or water meter with check valve provisions
for thermal expansion of water in the hot water system must be provided.
Figure 4. Typical Front Inlet Connection
Figure 5. Typical Front Inlet Connect with Storage Tank