Bradford-White Corp D80T725 Water Heater User Manual


 
SERVICE PROCEDURE PDV24-VIII
Anode Removal and Inspection
WARNING
Water Heater components may be HOT when performing the following steps in this
procedure. Take necessary precaution to prevent personal injury.
Step 1. Disconnect (unplug) water heater from electrical supply.
Step 2. Turn “OFF” water supply to water heater.
Step 3. Open a near by hot water faucet to relieve tank pressure.
Step 4. Connect hose to drain valve of water heater and route to an open drain. Open
drain valve and drain a minimum of 5 gallons of water from the water heater.
Close drain valve and disconnect drain hose from water heater.
Step 5. If required, disconnect top plumbing connection from top of water heater.
Step 6. Remove screws holding jacket head to top of water heater
and remove jacket head from top of water heater. Note, it may
be necessary to use a screw driver to pry underneath
jacket head (see photos at right).
Step 7. Remove insulation from top of water heater to expose collector cover,
if necessary. (see bottom of page for approx. anode locations)
Step 8. Remove screws from top (or sides) of collector cover. Note, it may be
necessary to chisel away some foam to access screws.
Step 9. Locate and remove anode rods from top of water heater (1-1/16 hex socket).
Step 10. Visually inspect anode rod. Anode rod may show signs of depletion;
this is normal. If the anode shows signs of depletion
(approximately 5/8", see photo at right), replacement is recommended. If any of
the steel core of the anode is exposed, replacement is recommended.
Step 11. Upon completion of inspection or subsequent replacement,
reinstall anode rods into water heater.
Step 12. Check for leaks.
Step 13. Reinstall collector cover & insulation over collector cover, if applicable.
Step 14. Reinstall jacket head.
Step 15. Reconnect plumbing connection to top of water heater if required.
Step 16. Restore water supply and power to water heater.
Step 17. Verify proper operation.
Replace Anode
42