Bradford-White Corp D65T625 Water Heater User Manual


 
38
SERVICE PROCEDURE PDV24-V
Main Burner & Pilot
Removal and Inspection
WARNING
Water Heater components may be HOT when performing the following steps in this
procedure. Take necessary precaution to prevent personal injury.
Main Burner Removal
Step 1. Disconnect (un-plug) water heater from
electrical supply.
Step 2. Turn “OFF” gas supply to water heater.
Step 3. Rotate gas valve control knob to the “OFF” position
(see photos at right).
Step 4. Disconnect Gas supply line from the gas valve.
Step 5. Disconnect wire leads from gas valve
(see photos at right).
Step 6. Disconnect white flame sense wire & orange ignition
wire from Control Board (see photos at right).
Step 7. Remove the two burner rack mounting screws (see photos).
Step 8. Slide complete burner rack out from water heater
(see photos below).
Step 9. To install burner, reverse above procedure.
Step 10. Check for gas leaks and verify proper operation.
Gas Valve
Control Knob
Gas Valve
Wire Leads
Burner Rack
Mounting
Screw
Pilot Draft
Shield
Pilot spark wire
(Orange)
Pilot Flame Sense
Wire (White)
INDUCED DRAFT MODELS
Burner Rack
Mounting
Screw