Bradford-White Corp D65T625 Water Heater User Manual


 
FEATURES OF HONEYWELL INTEGRATED CONTROLS SYSTEM
Attractive digital water heater display on control panel for setting and displaying the temperature
setpoint. Pressing temperature up and down buttons changes the temperature setpoint. Same
water heater display used on all models. Temperature format may be displayed in degrees F or
degrees C.
Single control board with plug in wiring controls temperature, ignition, and blower operation.
Reduced number of parts for servicing and wiring.
Plug in wiring reduces chance of miswiring.
Water heater display will show diagnostic codes in the event the water heater needs servicing.
Aids in diagnosing and servicing the water heater.
Water heater display can show previous error code history to further aid in servicing the water
heater.
FEATURES OF PDV-S MODEL SERIES
Power vented direct vent design, uses a blower to vent the flue products to the outside and pull combustion air in
from outside the building
Independent Venting - Exhausts flue products and supplies combustion air through two separate 3" or 4" PVC,
CPVC or ABS pipes. Maximum venting distance of 40 ft. with one 90 degree elbow for each pipe in 3". The
250,000 Btu/hr. model vents with 4" PVC, CPVC, or ABS only. Maximum vent length is 55 feet with one 90
degree elbow in 4" pipe (each pipe) for all models.
Electronic ignition - Pilot is automatically lit and monitored by the Honeywell Integrated Ignition Control system.
Main burners light from the pilot. Pilot and main burners shut off at the end of each water heating cycle.
Electronic thermostat and LCD Display - Accurately monitors the tank temperature and the setpoint is easily
adjusted by using the temperature UP and DOWN buttons on the display on the control box cover.
FEATURES OF PDV-T MODEL SERIES
Power vented direct vent design, uses a blower to vent the flue products to the outside and pull combustion air in
from outside the building
Co-axial Venting (pipe inside a pipe) - Combustion air enters from outside the building through an outer pipe and
exhausts flue products through the inside pipe. May be vertically or horizontally vented with a maximum venting
distance of 19'-6" (19 feet, 6 inches) with one 90 degree elbow.
Electronic ignition - Pilot is automatically lit and monitored by the Honeywell Integrated Ignition Control system.
Main burners light from the pilot. Pilot and main burners shut off at the end of each water heating cycle.
Electronic thermostat and LCD Display - Accurately monitors the tank temperature and the setpoint is easily
adjusted by using the temperature UP and DOWN buttons on the display on the control box cover.
FEATURES OF INDUCED DRAFT MODELS
High Capacity power vented design, uses a blower to pull the flue products out the water heater. Designed to
vent vertically through 8 inch diameter type B venting system. Uses room air for combustion.
Electronic ignition - Pilot is automatically lit and monitored by the Honeywell Integrated Ignition Control System.
Main burners light from the pilot. Pilot and main burners shut off at the end of each water heating cycle.
Electronic thermostat and LCD Water Heater Control Display - Accurately monitors the tank temperature and the
setpoint and is easily adjusted by using the temperature UP and DOWN buttons on the display on the control box
cover.