4 System Configuration notifications
4.1 Introduction
This chapter defines the set of update notifications concerning SC send by the CCU.
4.1.1 Update Notification item explanation
Each description consists of the following items:
Purpose
A global description of the purpose of the notification.
Notify structure with this update
The information passed with the update notification.
4.1.2 Unit/user event relations
In the previous chapter a description is given of each remote function with a summary of update notifications
being the result of executing that function. However, update notifications are also the results of user actions
done on the actual units or CCU’s. This section gives unit/user event matrices for the SC application in which
the possible user events are linked with the corresponding update notification(s) depending on the system
set-up. For some events also the required remote functions to continue SC monitoring and maintaining are
given.
The update notifications themselves are described in the remaining sections of this chapter. The
recommended functions from the SI group are described in chapter 5.
UNIT-EVENT MATRIX
Single CCU System (Remote Controller connected as specified in [SRS_INF])
Event Update Notification Continue with remote function
Switch On CCU SC_C_CCU_REBOOT SC_C_START_DCN
Recommended before continuing:
SC_C_GET_CCU_VERSIONINFO
SC_C_GET_CCU_CONFIG
SI_C_START_INSTALL and run
installation as described in
example-1 in Appendix Appendix C
Connect a unit SC_C_CONNECT_UNIT Recommended before continuing:
SI_C_START_INSTALL and run
installation as described in
example-2 in Appendix Appendix C
Disconnect a unit SC_C_DISCONNECT_UNIT
Multi CCU System (Remote Controller connected to the Master as specified in [SRS_INF])
Event Update Notification Continue with remote function
Switch On a Slave
CCU, while Master CCU
is still off
<None>
Switch On Master CCU SC_C_CCU_REBOOT SC_C_START_DCN
Recommended before continuing:
SC_C_GET_CCU_VERSIONINFO
SC_C_GET_CCU_CONFIG
SI_C_START_INSTALL and run
installation as described in
example-1 in Appendix Appendix C
Switch On a Slave CCU SC_C_CONNECT_SLAVE_CCU
and a few seconds later for
every unit connected to that
Slave CCU separately
SC_C_CONNECT_UNIT
Recommended before continuing on
the unit connect updates:
SI_C_START_INSTALL and run
installation as described in
example-2 in Appendix Appendix C
Switch Off a Slave
CCU
SC_C_DISCONNECT_SLAVE_CCU
Connect a Unit SC_C_CONNECT_UNIT Recommended before continuing:
SI_C_START_INSTALL and run
installation as described in
example-2 in Appendix Appendix C
Disconnect a Unit SC_C_DISCONNECT_UNIT