Appendix B Installation Checklists
A simplified guide for those who are already familiar with installing and program-
ming Allegiant systems.
MAIN BAY HARDWARE INSTALLATION
✔
Unpack equipment and verify that items have been received without carrier damage.
✔
Install power supply (do not turn ON) and CPU module.
✔
If applicable, install bay into EIA 19-inch rack (remember to remove rubber bumper
foot pads.
✔
Install video input module(s) following proper termination procedures. Install video
output module(s).
✔
Connect camera inputs and monitor outputs to appropriate connections on equip-
ment bay(s).
✔
Connect system keyboards, any alarm interface unit(s), and any signal distribution
unit to the main bay.
✔
Set CPU DIP switches to activate desired features.
✔
Apply main AC power to equipment.
✔
Verify system is operating properly then begin appropriate programming.
PROGRAMMING VIA SYSTEM KEYBOARD
✔
Enter system time (User Function 7) and date (User Function 8). Enter Camera ID
titles (User Function 9), and if desired, adjust monitor overlay displays (User Function
4, 5, & 6 or 24, 25 & 26).
✔
Enter desired Sequences.
✔
Configure and test alarm response mode.
SATELLITE CONFIGURATION HARDWARE INSTALLATION
Main Site:
✔
Install main Allegiant bay and appropriate accessory products accordingly. Verify
the biphase control code line is run to each satellite site.
✔
Attach trunk line inputs, local camera inputs, and monitor outputs to the main Alle-
giant bay. Apply main AC power to equipment.
✔
Program Camera ID Table using the LTC 8059 MCS package.
✔
Switch all unused monitor outputs located at the main site to display a 'local' cam-
era input.
Satellite Site(s):
✔
Install satellite switcher and appropriate accessory products accordingly.
✔
Connect the biphase code line to the LTC 8780 Data Converter unit and configure
according to the desired satellite address and switcher's baud rate.
✔
If necessary, program the satellite switcher for the desired camera titles and any
other related requirements.