Beckett CF375 Burner User Manual


 
2
To the Owner:
Thank you for purchasing a Beckett
burner for use with your heating appliance.
Please pay attention to the Safety Warnings
contained within this instruction manual.
Keep this manual for your records and
provide it to your quali ed service agency
for use in professionally setting up and
maintaining your oil burner.
READ THESE INSTRUCTIONS AND
SAVE FOR REFERENCE
Your Beckett burner will provide years of
ef cient operation if it is professionally
installed and maintained by a quali ed
service technician. If at any time the burner
does not appear to be operating properly,
immediately contact your quali ed
service agency for consultation.
We recommend annual inspection/
service of your oil heating system by a
quali ed service agency.
Daily – Check the room in which your
burner/appliance is installed. Make sure:
Air ventilation openings are clean and
unobstructed
Nothing is blocking burner inlet air
openings
No combustible materials are stored
near the heating appliance
There are no signs of oil or water
leaking around the burner or appliance
Weekly
Check your oil tank level. Always
keep your oil tank full, especially
during the summer, in order to prevent
condensation of moisture on the inside
surface of the tank.
y
y
y
y
y
Contents
General Information ....................................................3
Hazard De nitions ........................................................................3
Agency approvals ..........................................................................3
Speci cations ................................................................................3
Owner’s Responsibility: .................................................................4
Pre-Installation Checklist............................................4
Combustion air supply ...................................................................4
Clearances .................................................................................... 4
Professional Installer/Service Agency Responsibility: ...................4
Fuel supply ....................................................................................5
Nozzle pressure ............................................................................5
Electrical supply ............................................................................5
Inspect Chimney or Direct Vent System ........................................6
Verify burner components .............................................................6
Verify ring rate .............................................................................7
Verify air tube ................................................................................7
Stray Light .....................................................................................7
Dust and Moisture .........................................................................7
Mount the Burner .........................................................8
Mount ange(s) on air tube ...........................................................8
Mount air tube to burner ................................................................8
Install nozzle .................................................................................8
Check electrode settings ...............................................................8
Install nozzle line assembly ...........................................................8
Set dimension Z ............................................................................9
Insert burner ..................................................................................9
Fuel unit by-pass plug ...................................................................9
Installing the oil tank and supply system .......................................9
Fuel line valves and lter ...............................................................9
Wire the Burner .......................................................... 10
Burner fuel ow ...........................................................................10
Typical Burner Sequence of Operation - 7505 Control. ..............12
Typical Burner Wiring - 7505 Control ..........................................13
Reset Button Operation ...............................................................13
Typical Burner Sequence of Operation - R7184P Control. .........14
Typical Burner Wiring - R7184P Control. ....................................15
Prepare the Burner for Start-up ............................... 15
Start-up checklist .........................................................................15
Start the Burner ......................................................... 16
Starting the burner and venting air ..............................................16
Initial head position .....................................................................16
Initial air settings .........................................................................16
Set appliance limit controls .........................................................16
Prepare the fuel unit for air venting .............................................16
Disable function (7505 or R7184 Controls) .................................17
Cad Cell Resistance Measurement .............................................17
Resetting From Restricted or Hard Lockout ................................17
Set combustion using instruments ..............................................17
Maintenance and Service.......................................... 18
Replacement Parts .................................................... 19
Limited Warranty Information .................................. 20