Beckett CF2300 Burner User Manual


 
17
Form 6104 BCF23-R05
Table 4a. CF1400 Initial indicator
adjustment plate settings
Figure 12 – Adjusting plate initial setting, typical
Table 4b. CF2300 Initial indicator
adjustment plate settings
CF1400
Tube
Head Position Damper Position
Approximate
Head Setting
Firing Rate
(gph)
Approximate
Air Damper
Setting
Firing Rate
(gph)
A
0 4.00 0 --
1 4.50 10 --
2 5.00 20 4.00
3 6.00 30 5.00
4 7.00 40 7.00
5 7.50 50 8.00
6 8.00 60 10.00
7 9.00 70 11.00
8 9.50 80 --
9 10.00 90 --
10 11.00 100 --
-- -- 110 --
-- -- 120 --
B
0 7.00 0 --
1 7.50 10 --
2 8.00 20 --
3 9.00 30 --
4 10.00 40 7.00
5 10.50 50 8.00
6 11.00 60 10.00
7 12.00 70 11.00
8 13.00 80 12.00
9 13.25 90 12.50
10 13.60 100 13.00
-- -- 110 13.25
-- -- 120 13.60
CF2300
Tube
Head Position Damper Position
Approximate
Head Setting
Firing Rate
(gph)
Approximate
Air Damper
Setting
Firing Rate
(gph)
A
011.00--
1 12.0 10 7.0
2 13.0 20 10.0
3 14.0 30 13.0
4 15.0 40 14.0
5 16.0 50 15.0
6 17.0 60 16.0
7 18.0 70 17.0
8 19.0 80 18.0
9 20.0 90 19.0
-- -- 100 20.0
B
0 12.5 0 --
1 13.0 10 10.0
2 14.0 20 13.0
3 15.0 30 14.0
4 16.0 40 15.0
5 17.0 50 16.0
6 18.0 60 17.0
7 18.5 70 18.0
8 19.0 80 18.5
9 20.0 90 19.0
-- -- 100 20.0
Legend
b
Spline nut for securing nozzle line
c
Bottom acorn nut (for head adjustments)
d
Top acorn nut (for setting dim. Z only - do not
loosen after setting Z)
e
Indicator adjusting plate
f
Secondary adjusting plate
g
Primary adjusting plate
h
Copper oil line from oil valve to nozzle line