6 Specifications
© Travis Industries 4080725 100-01154
Heating Specifications
Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet
Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5
Maximum Burn Time on Low Burn** ......................................................................67.5 Hours
Hopper Capacity ..............................................................................................115 Pounds
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected
by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel
quality may occur.
Dimensions
Weight: 250 Lbs.
Air Inlet
(1-3/4"
Outside
Diameter)
4"
Diameter
Exhaust
10-1/2”
17-5/8"
1/2"
7-1/4"
Center
Line
33-3/8"
26-1/2"
28"
This tab is for
the scraper
rod tool.
Electrical Specifications
Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)
Fuel
• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.
See page 25 for details on using a corn pellet mix.
EPA Compliance
This heater has been tested exempt from EPA Phase II Requirements by OMNI-Test Laboratories, Inc.