Operation 25
© Travis Industries 4080725 100-01154
Start-Up Sequence
This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started
when cold. This is to ensure proper operation through all possible settings and operational states (hot
or cold, pellets burning or not burning, etc.). This sequence over-rides all user settings (except the
"OFF" position) to set the auger feed rate to medium, the exhaust blower to high, and the igniter on.
During this period the lowest “HEAT OUTPUT” light will flash.
"AUGER ON" Light
This light comes on when the auger is turning. This allows the operator to determine when the auger
is turning.
"MAINTENANCE REQUIRED" Light
NOTE : If the “MAINTENACE REQUIRED” light
comes on, check the items below before calling
for service .
The “MAINTENACE REQUIRED” light is used to
indicate maintenance is required on the heater. It
will turn on due to various operating circumstances.
When it turns on, a second light will turn on near
“HEAT OUTPUT” (see the illustration to the right).
Determine the maintenance code (2, 4, or 6), then
use the chart below to diagnose and remedy the
situation.
HIGH
DISCONNECT POWER BEFORE SERVICE
AUTO
MANUAL
H
E
A
T
O
U
T
P
U
T
MED
LOW
AUGER
# 6 Light
(red)
# 2 Light
(green)
# 4 Light
(yellow)
MAINT.
(REQUIRED)
Light Likely Cause Remedy
2
(green)
• Heavy Ash Build-Up in Exhaust Duct
• Heavy Ash Build-Up in Exhaust
Housing or Plugged Tubing
• Heavy Ash Build-Up in Vent
• Clean the Firebox (see page 34)
• Clean the Exhaust Housing and Tubing (see page
35)
• Clean the Vent (see page 35)
4
(yellow)
• Heater Ran Out of Pellets
• Heater Did Not Start-Up Correctly
• Power Outage
• Restrictor Not Set Properly
• Burnpot Clogged
• Air Leak
• Heavy Ash Build-Up
• Refill the Hopper (see page 21)
• Re-Start the Heater and Verify the Pellets Ignite
after 10 Minutes
• Re-Start the Heater (see page 26)
• Re-Start the Heater and Monitor Restrictor
Setting (see page 24)
• Clean Burnpot (see page 28)
• Verify Door, Glass, and Ashpan Seal Correctly
(see page 37)
• Clean the Firebox (see page 34), Exhaust
Housing (see page 35), and Vent (see page 35)
6
(red)
• Electrical Input Error (voltage or mhz
fluctuation, amp deficiency, etc.)
• Components Over-Heated
• Faulty Wiring / System Fault
• Unplug the Heater then Plug it Back In (this re-
starts the circuit board)
• Clean the Heater and Vent (a plugged heater will
slow exhaust flow, increasing temperatures –
see pages 34- 35)
• If this Fault Persists, Contact Your Dealer