8 Installation (For Qualified Installers Only)
© Travis Industries 4080725 100-01154
Clearances - Straight Installation
6” Minimum
3” Minimum
9” Minimum
Vent
Clearance*
Through the Wall Installations Interior Vertical Vents
Floor Protection
6” Minimum
2”
Minimum**
9” Minimum
“Tee”
Clearances - Corner Installation
6” Minimum
Through the
Wall Vents
3” Minimum
45° Elbow
45°
Interior Vertical
Vents
3”
Minimum
6” Minimum
Floor Protection
“Tee”
3” Minimum
3”
Minimum
Vent Clearance*
2”
Minimum**
* Install vent at clearance specified by the vent manufacturer.
NOTE: If interior vertical vent is used, the stove to backwall dimension is determined by the vent
being used. This dimension will vary depending on the brand of pellet vent used. To determine the
distance from the backwall to the stove, connect the "Tee" and add the vent clearance .
** The floor protection must extend 2” or to the wall (whichever is less) – all vent clearances must be met.