Avalon Stoves Rainier Stove User Manual


 
6 Features & Specifications
Travis Industries 100-01140 4020628
Installation Options:
Freestanding
Freestanding in an Alcove
Freestanding in a Mobile Home
Masonry Fireplace Insert
Factory-Built (Z.C.) Fireplace Insert
Features:
EPA Phase II Approved
1.8 Cubic Foot Firebox Volume
Single Operating Control
Accepts Logs Up to 20" Long
Steel Plate Construction (1/4" & 3/16")
Heavy Duty Refractory Firebrick
Optional High-Tech Blower
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* 800 to 1,800
Maximum BTU's per Hour (Cord Wood Calculation) 71,800
Overall Efficiency (Oregon Method) 71.7 %
Maximum Burn Time Up to 9 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions:
Insert Dimensions - Rainier 90
Depth into Fireplace** ........14-1/2"
Onto Hearth**** ....................5-1/8"
Insert Dimensions - Rainier 45
Depth into Fireplace** ...........9-1/2"
Onto Hearth**** .......................10"
25-3/4" ****
Note:
Measure side, corner,
and back clearances
from the stove top.
4-1/4"
21 1/8"*
19-3/8"
Height:
Steel Legs (discontinued)..27-5/8"
Sculptured or Cast Legs..........29"
Pedestal............................32-3/8"
The flue collar protrudes
3/4" above the stove top
3-5/8"
19-1/8"
(from base)
Flue Location for Rainier-45
* For inserts, add 3/4" for the flue collar.
** ZC (metal) fireplaces require an additional 1".
*** ZC (metal) fireplaces require an additional 2".
**** Does not include hearth protection.
Emissions:
2.0 Grams Per Hour (EPA Phase II Approved) Tests conducted by E.E.S.P.C.