Avalon Stoves Rainier Stove User Manual


 
36 Listing Label
Travis Industries 100-01140 4020628
MODEL:
Rainier 90 Rainier 45
990 (Top Flue) 945 (45° Flue)
10850 117th Pl. N.E. Kirkland, WA 98033
Manufactured By:
Combustible floor beyond hearth must be protected by a minimum 0.25 inches thick insulating board, having a thermal conductivity of K=0.72 BTUs in/Ft÷-hr °f at
800°f, or equivalent. (See Owners Manual for examples)
All fireplace installations require facing shroud plates. Do not remove firebrick or mortar from masonry fireplace. Install with or without a direct flue connection.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
Date of Manufacture
2002 2003 2004 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
DO NOT REMOVE THIS LABEL Made in U.S.A.
0338 (IGN)
Serial Number
Tested to: UL 1482 AND APPLICABLE SECTIONS OF UL 127, 737 AND 907.
FOR USE WITH SOLID WOOD FUEL ONLY
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
INSTALLATION AND RESTRICTIONS IN YOUR AREA.
ROOM HEATER SOLID FUEL TYPE APPLIANCE ALSO FOR USE IN MOBILE HOMES
SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES.
DO NOT REMOVE THIS LABEL
Report #028-S-45-4
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturers installation and operating instructions. Contact your local building
or fire officials about restrictions and installation inspection in your area. Refer to local building codes and manufacturers instructions for precautions
required for passing a chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not
connect this unit to a chimney flue serving another appliance. Clearances may be reduced by methods specified in NFPA211, listed wall shields, pipe
shields, or other means approved by local building or fire officials. Inspect and clean chimney frequently, under certain conditions of use creosote build
up may occur rapidly. Do not overfire. If heater glows, you are overfiring. Maintain 36 front clearances to all furnishings and other combustible
materials. Do not use grate or elevate fire, build wood fire directly on hearth. Operate only with door closed.
OPTIONAL EQUIPMENT: Front or rear blower (electrical rating: 115V, 60 Hz., 1.8 Amps)
Replace glass only with AVALON supplied NEOCERAM ceramic glass (5mm).
Do not route power cord under or in front of appliance.
DURAVENT model DVL with DURA-PLUS chimney
AMERI-TEC model DCC with model HS chimney
SECURITY model DP with SECURITY model ASHT or S2100 chimney
GSW model Super Chimney Twenty-One connected directly to appliance
SELKIRK METALBESTOS model DS connector with model SSII chimney
DURAVENT Model DVL with DURA-TECH chimney
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6 diameter, minimum 24 MSG black or 25 MSG blued steel connector,
with listed UL-103 HT factory-built chimney, suitable for use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required. Maximum alcove
depth 48, minimum alcove height 84.
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition,
mobile home installations require outside air - use the Avalon Rainier optional pedestal or outside air boot.
Pedestal or legs are required.
COMBUSTIBLE FACING
MANTEL
HEARTH EXTENSION
INSERT
COMBUSTIBLE SIDEWALL
NON-COMBUSTIBLE
FIREPLACE FACING
AB
C
D
F
E
LISTED FIREPLACE INSERT FOR INSTALLATION INTO A FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE
Minimum Clearance to Masonry Factory-Built
Combustibles and Hearth Fireplace (Z.C.) Fireplace
Requirements Installations Installations
A. 14.0” 30.0”
B. 13.0” 12.0”
C. 29.5” 12.0”
With Shield 14.5” N/A
D. 31.5” 24.0”
With Shield 16.5” N/A
Hearth Extension Front 16” 16”
Hearth Extension to Sides 8” 8”
Rainier 90
Singlewall connector
Conventional residential
Installation
Rainier 45
Singlewall connector
Conventional residential
Installation
Rainier 45
Alcove, Mobile home, and reduced
clearance conventional residential
Installation
Rainier 90
Alcove, Mobile home, and reduced
clearance conventional residential
Installation
A.
B.
C.
D.
E.
F.
Sidewall to Unit
Backwall to Unit
Corner to Unit
Sidewall to Connector
Backwall to Connector
Corner to Connector
14.0 in.
14.5 in.
11.0 in.
24.0 in.
15.75 in.
20.0 in.
14.0 in.
09.5 in.
07.5 in.
23.5 in.
10.25 in.
16.0 in.
14.0 in.
17.5 in.
11.0 in.
24.0 in
15.5 in.
16.5 in.
16.0 in.
14.0 in.
07.5 in.
25.5 in.
10.0 in.
12.0 in.
Minimum Clearance to Combustible Materials - Freestanding Installation
Freestanding Clearance Diagram
Floor Protection Diagram
Alcove Specifications
Max. Alcove Depth 48 in.
Min. Alcove Height 84 in.
Min. Alcove Width
990: 53.5 in.
945: 57.5 in.
Floor protection must be a non-com-
bustible material extending beneath the
heater and to the front, sides and back
as indicated. See Owner's Manual for
examples of non-combustible materials
that can be used.
FRONT
STOVE
FLOOR PROTECTOR
6
6
6
16
45˚
STOVE
STOVE
ADJACENT WALL
ADJACENT WALL
BACKWALL
SIDEWALL
E
D
F
B
A
C
Factory-Built (Z.C.) Fireplace installations require a minimum 24 starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.)
Fireplace chimney must have a minimum cross-sectional area of 28.85. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or secured in the
open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturers installation instructions. Factory-Built (Z.C.) Fireplace floor protection
must be 3/8 minimum non-combustible material or equivalent, extending 16 in front of insert and 8 to both sides. A metal deflector plate must be installed if the
flue collar is not completely behind the lintel plate of the Factory-Built (Z.C.) Fireplace openings.