Avalon Stoves Rainier Stove User Manual


 
22 Insert Installation (for qualified installers only)
Travis Industries 100-01140 4020628
Insert with
Direct
Connection
(Z.C.
Fireplace)
NOTE:
Direct
connections
require installation
of an airtight
block-off plate or
damper adapter
(see "Block-off
Plate Installation"
on page 20).
Block-off plate or
damper adapter
Stainless steel
chimney connector
must Extend 1' past
the block-off plate.
Combustible Mantle
See the section
"Insert Placement
Requirements" for
minimum clearances
and hearth required.
Surround Panels
NOTE: This installation may be
used with a masonry or zero
clearance fireplace. This
illustration depicts a zero
clearance insert, all requirements
in the section "Zero Clearance
Fireplace Requirements" must be
fulfilled prior to installation.
Z.C. (Metal) firebox
Optional
Telescoping Legs
No modification to the firebox
of the z.c. fireplace is allowed.
Damper must
be removed
Insert with
Face Seal
Connection
NOTE:
Face seal
connections
require installation
of the surround
panels and
insulation (see the
"Surround Panel
Installation" on
page 41).
Remove damper
or wire it open
Airtight Insulated
Clean-Out
Combustible Mantle
NOTE: This installation may be
used with a masonry fireplace
only. The requirements in the
section "Masonry Fireplace
Requirements" must be fulfilled
prior to installation.
Flue
Liner
See the section "Insert
Placement Requirements"
for minimum clearances
and hearth required.
Surround Panels with
insulation (see "Surround
Panels" installation
instructions in the back of
the manual)
NOTE: It is
recommended your
chimney have a
minimum 28 and a
maximum of 144
square inch cross-
sectional area to use a
face seal connection,
otherwise your
chimney maynot have
sufficient draw for the
fireplace insert to
operate correctly.