Avalon Stoves Rainier Stove User Manual


 
Insert Installation (for qualified installers only) 19
Travis Industries 100-01140 4020628
Masonry Fireplace Requirements
Chimney must have a clay tile liner or a stainless steel liner (positive connection)
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Chimney height: 15' minimum; 33' maximum.
Entire fireplace, including chimney, must meet local building requirements
Zero-Clearance (Metal) Fireplace Requirements:
Must utilize a positive (full reline) or direct connection (block-off plate)
Must be manufactured by one of the following manufacturers:
Marco Majestic Heatilator Preway Tempco Superior
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Entire fireplace, including chimney, must meet local building requirements
Chimney height: 15' minimum; 33' maximum. Minimum
cross section: 28.65 square inches
The damper ("A") and grate ("B") must be removed (see
the illustration to the right)
The smoke shelf ("C"), internal baffles ("D"), screen ("E"),
and metal or glass doors ("F") may be removed (if
applicable)
The masonry lining ("G"), insulation ("H"), and any
structured rigid frame members (metal sides, floor, door
frame, face of the fireplace, etc. "I") may not be
removed or altered
C
B
F
I
D
E
A
G
H
Drafting Performance
This appliance relies upon natural draft to operate. External forces, such as wind, barometric
pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air
infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external
forces leading to less than optimal performance.
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install,
raise the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the
insert. Adjust the bolts until they extend the same height as the hearth steps up. After the insert is
installed, fine-tune the leveling bolts to level the insert (see the illustration).
This distance is the
hearth step-up. The
leveling bolts should
stick out this far from the
base of the insert.
Fireplace
Hearth
The leveling bolts go
into the holes at the
rear corners of the
insert.