Avalon Stoves Arbor PS Stove User Manual


 
36 Maintenance
© Travis Industries 4070806 100-01191_000
Yearly Maintenance (or every two tons) - continued
Clean the Exhaust Blower
The exhaust blower cover is held in place with 4 screws.
Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.
Remove the
side cover.
Remove these 3 nuts to
expose the exhaust blower.
Use the bottle brush to disoldge any
flyash near the exahust blower and in the
horizontal exhaust channel. Take care
to not damage the impeller on the
exhaust blower.