Stove Installation (for qualified installers only) 7
© Travis Industries 100-01190_000 4070326
SAFETY NOTICE:
Please read this entire manual before you install and use your new room heater. Failure
to follow instructions may result in property damage, bodily injury, or even death.
Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Always use gloves when operating a hot stove. The door handles, loading lid, bypass handle, and other
components become very hot during normal use.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
Preparation for Installation
• Check for damage to the exterior of the stove.
• Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened for transportation by removing the doors, loading lid, and firebricks. Replace
these components before operation.
• Install the bypass handle (included in the owner’s pack - see page 10).
Stove Installation Considerations
The table below details the six most common types of installations and the considerations for each type.
Alternative methods of installation are available if they comply with local building codes.
Installation Type Considerations
Standard Ceiling with a Factory Built Chimney
(Page 16)
• Requires ceiling and roof penetration
• Provides best draft
Cathedral Ceiling with a Factory Built Chimney
(Page 16)
• Cathedral style chimney support required
• Provides best draft
Hearth Stove Positive Connection
(Page 17)
• Utilizes existing masonry fireplace (not approved for zero
clearance (metal) fireplaces)
• Provides good draft due to full reline
• Easier to clean than direct or horizontal hearth stove
Hearth Stove Direct Connection
(Page 17)
• Utilizes existing masonry fireplace (not approved for zero
clearance (metal) fireplaces)
• Requires construction of a "block-off plate"
• Draft reduced due to elbows & chimney cross section
Interior Masonry Chimney
(Page 18)
• Utilizes existing masonry chimney (not approved for zero
clearance (metal) fireplaces)