Ariens 915502 Air Cleaner User Manual


 
11 - 42
11.13 CONTINUITY DIAGRAM
PTO Switch
87
Key Switch
Relay
Seat Switch
Parking Brake Switch
Neutral Switch
Solenoid
Not Energized Energized Button Out Button In
Operator
Off Seat
Button Out Button InOperator
On Seat
Disengaged
(down position)
Disengaged
(down position) Not Energized Energized
Off Run / Light Run
Start
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.
3
9
417
12 12
86
30
87A
85
3
9
417
87
86
30
87A
85
PE0770
For Serial Numbers Above 10,000