FIGURE 9
WIRE FENCE
When the water heater outlet terminal is low enough to be touched
accidentally, or is accessible to small children, a wire mesh chain link
fence (as shown in Figure 9) may be used. Care should be taken to
maintain adequate ventilation around the outlet terminal. If a chain link
fence is installed, it must not be used as a storage area for items that
may block proper ventilation.
FIGURE 9
WARNING
THE LOCATION SELECTED MUST PROVIDE CLEARANCES FOR SERVICING
AND PROPER OPERATION OF THE WATER HEATER.
WARNING
VENT TERMINATION MUST NOT BE WITHIN 4 FEET OF ANY ITEMS SUCH AS GAS
METERS, GAS VALVES OR OTHER GAS REGULATING EQUIPMENT.
WARNING
FAILURE TO HAVE REQUIRED CLEARANCES BETWEEN WATER HEATER
AND COMBUSTIBLE MATERIAL WILL RESULT IN A FIRE HAZARD.
FIGURE 7
FACTS TO CONSIDER ABOUT THE LOCATION
VENTING THROUGH ROOF-CLEARANCES
1" (2.5 cm) clearance for 4" or 6" PVC or CPVC piping from
combustible surfaces for outlet piping.
0" clearance for 4" or 6" PVC or CPVC piping from combustible
surfaces for inlet piping.
The Power Direct Vent inlet and outlet terminals shall terminate at
least 18" (46 cm) above the roof surface. See Figure 10.
The venting system must be installed in a manner which allows
inspection of the installation of the venting pipes and joints as well as
periodic inspection after installation as required by ANSI Standards.
FIGURE 8 - DIRECT VENT TERMINAL CLEARANCES - US INSTALLATION