Amtrol OWB Series Boiler User Manual


 
Shutoff Valve
Circulatin
g
Pum
p
s
Stem Thermo
m
ete
r
Su
pp
l
y
to S
y
ste
m
Return from S
y
ste
m
B
yp
ass A
S
R
Cold Water Feed
Drain Coc
k
Circulatin
g
Pum
p
s
Adjust the two manual valves to maintain 160 degree F or more in the boiler while holding the supply water
temperature at the stem thermometer at 140 degree F or whatever minimum temperature system requires.
Figure 20.
NOTE
Bypass A shown in figure 20. above should not exceed 12 inches in length. If it
is not practical to maintain a 12 inch length or less then increase the pipe size o
f
the bypass by one size.
4. LARGE WATER CONTENT SYSTEMS------
Such systems as converted gravity systems, old systems with cast iron radiators, and
also newer systems that employ outdoor reset control present a potential problem with
low return water temperatures and condensation. The boiler must be protected from
condensation in such cases by using a by-pass as shown in Figure 21.
26
Installation, Operation, And Service Instructions