ADT Security Services Safewatch Pro 2000 Smoke Alarm User Manual


 
– 30 –
TROUBLE CONDITIONS (Continued)
Words or letters in parentheses ( ) are those that are displayed on English Display
Touchpads
.
Other Trouble
Displays
* Any “beeping” that
accompanies a
trouble display can be
stopped by depress-
ing any key on the
touchpad or by
entering an OFF
sequence (code +
OFF)
** Not all systems use
wireless sensors.
1. COMM. FAILURE Indicates that a failure has occurred in the telephone com-
(or FC) munication portion of your system.
CALL FOR SERVICE IMMEDIATELY.
2. SYSTEM LO BAT Indicates that a low system battery condition exists. Display
(or BAT with no zone No.) is accompanied by "beeping"* at the Touchpad. If this
condition persists for more than one day (with AC present),
CALL FOR SERVICE.
3. LO BAT + zone descriptor Indicates that there is a low battery condition in the wireless
(or BAT with zone No.) transmitter** number displayed. Accompanied by a single
"beep"
*
(once every 40 seconds) at the Touchpad.
Either replace the battery yourself, or CALL FOR SERVICE.
If the battery is not replaced within 30 days, a CHECK
display may occur.
4. Rcvr Jam Wireless part of the system is experiencing RF interference
(or CHECK 90) which may impede reception from wireless sensors.**
5. MODEM COMM
(or CC)
Indicates that the control is on-line with the Customer Care
Center's remote computer. The control will not operate
while on-line. Wait a few minutes. Display should disappear.
6. BELL FAILURE Indicates that the wiring connection to the external sounder
(or CHECK 70) is at fault (open or shorted). Accompanied by “beeping” at