ADT Security Services ADT-UDACT Home Security System User Manual


 
Document 50934 Rev B 5/15/00 PN 50934:B
20
Primary Number Communication Format (16)
One location is needed to select the Communication Format to the primary phone
number. Address 16 is used for this purpose. The default (factory setting) for this
address is 16_A, which is 4+2 Standard, 1800 Hz 'Carrier', 2300 Hz 'ack'. You may
enter 0, 1, 2, 4, 6, 8, C or E in place of the default, then press [ENTER/STORE].
When selecting the Format, note that Ademco Contact ID is the only format in the
ADT-UDACT which identifies the specific zone or point status to the Central Station.
All other formats report the number of zones or points that are active but do not
identify the specific zone or point. Choose from the list of formats below:
0: 4+1 Ademco Express Standard, DTMF, 1400/2300 ACK
1: 4+2 Ademco Express Standard, DTMF, 1400/2300 ACK
2: 3+1 Standard 1800 Hz Carrier, 2300 Hz ACK
3: Not Used
4: 3+1 Standard 1900 Hz Carrier, 1400 Hz ACK
5: Not Used
6: 4+1 Standard 1800 Hz Carrier, 2300 Hz ACK
7: Not Used
8: 4+1 Standard 1900 Hz Carrier, 1400 Hz ACK
9: Not Used
A: 4+2 Standard 1800 Hz Carrier, 2300 Hz ACK
B: Not Used
C: 4+2 Standard 1900 Hz Carrier, 1400 Hz ACK
D: Not Used
E: Ademco Contact ID
F: Not Used
Note: Consult your Central Station for proper selection or consult our factory
representatives. For any format chosen, the ADT-UDACT automatically
programs all of the event codes. See Tables 3-2, 3-3, 3-4, 3-5, 3-6 and 3-7.
Primary Number Account Code (17-20) Four locations at addresses 17-20 default to
all '0's. Valid entries are (0-9 and A-F). The number of digits entered must match the
format selection. If programming '2 or 4' into address 16, enter 3 digits. (location 20 is
ignored) If programming '0, 1, 6, 8, A, C, or E' into address 16, enter 4 digits.
Primary Number 24 Hour Test Time (21-24).
Use military time when entering the 24 hour 'test' time. The 24 hour test report to
phone number 1 takes up four locations, from addresses 21-24. The default is 00:00
(12:00 midnight). The limits for each location are as follows: 21: enter 0, 1 or 2; 22:
enter 0-9; 23 : enter 0-5; 24: enter 0-9. Note: Do not use A-F.
Primary Number 24/12 Hour Test Time Interval (25). The test report sent to the
Primary phone number may be sent every 12 or 24 hours. If the message is to be sent
every 24 hours, leave the factory default entry of zero. If 12 hour test report time is
needed, enter 1=12 hours.
Secondary Phone Number (26-41). Programming is similar to programming the
primary phone number located at addresses 00 - 15. The defaults are also all 'F's.
FFFFFFFFFFFFFFFF
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41.