ADT Security Services ADT-UDACT Home Security System User Manual


 
Document 50934 Rev B 5/15/00 PN 50934:B
18
3.0 Programming Instructions
Programming Mode
___7
__77
_776
7764
Note that as you enter information into the
ADT-UDACT, the digits will scroll across the
display from right to left
3.1 Entering
Program Mode
You are allowed a pause of up to 10 seconds in between each number while entering
the code. After pressing the [ENTER/STORE] key, the ADT-UDACT will be in
Program Mode and display 00_F. You are allowed up to ten minutes of idle time at
this point before starting your programming, otherwise the ADT-UDACT will go
back to Normal Mode. You also have a maximum of 10 minutes between any key
stroke. All entries made prior to the 10 minute time-out are valid and stored.
Once in Programming Mode, the ADT-UDACT will:
Ignore the Test and Clear keys.
Continue to communicate any events not previously acknowledged at the
Central Station prior to entering Programming Mode.
Location 56 is factory set to = 0, ADT-UDACT communications disabled. This keeps
the communicator off until location 56 is changed to 1, 2, 3 or 4. Refer to program
selection for address 56 in this section. Once location 56 is changed from 0 and a
valid phone number is entered, transmission of the "ADT-UDACT off Normal" report
will occur.
Programming of the ADT-UDACT is possible at any time including while the
ADT-UDACT is communicating with a Central Station.
The ADT-UDACT has been designed for many different types of applications. After
examining your specific application, review the programming options and choose the
entries best suited for your system.
The ADT-UDACT has a built-in programmer. All programming selections are stored
in nonvolatile Electrically-Erasable Programmable Read-Only Memory (EEPROM).
This ensures that the ADT-UDACT will retain all entries made in programming mode
even if both AC and battery power are removed.
The user must program the primary and secondary phone numbers, account numbers
and 24 hour test report times for each Central Station account and the current time.
The ADT-UDACT comes with factory chosen options/features already programmed.
Other options/features may be programmed if desired. If all factory default settings
are acceptable, programming is complete.
To enter the Program Mode, press the MODE key once, (the display will go blank)
you then have ten seconds to start entering the code (7764) .
7764 spells PROG on a Touch-Tone® phone
If an incorrect key is entered, reenter the proper 4-digit code before pressing the
[ENTER/STORE] key