Acclaim Lighting 2490 Stove User Manual


 
15
Resolute
®
Acclaim Woodburning Stove
2000893

The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in-
stallations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances
must adhere to the guidelines stated in the Clearance Chart on Page 12.

 
 
   
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
27¹⁄₂ 26” 25¹⁄₂ 20¹⁄₂ 15” 18¹⁄₂
(699 mm) (660 mm) (648 mm) (521 mm) (381 mm) (470 mm)
ST608
Resolute Acclaim
flue centerline
Diagrams
1/01
*
A
B
C
*
D
E
F
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page:
35” in the United States and 37” (940mm) in Canada.

 
 
   
Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F)
27¹⁄₂ 17” 25¹⁄₂ 20¹⁄₂ 11” 18¹⁄₂
(699 mm) (432 mm) (648 mm) (521 mm) (279 mm) (470 mm)
ST608
ST608a
Resolute Acclaim
flue centerline
Diagrams
1/01
A
B
C
D
E
F
**To locate center of flue collar for corner installation, add 10¹⁄₂” (270mm) to the clearance distance from stove corner to wall.
Mark off the resulting distance from the corner along both walls. Next, measure the same distance from these two points out
from the walls. These last two measurements will meet at a point representing the center of the flue collar. Refer to the dia-
grams above.
ST608a